Configuring the DSU/CSU

Accessing and Displaying Configuration Options

To display the configuration options, you must first copy one configuration option set into the edit area.

"Procedure

To load a configuration option set into the configuration edit area:

1. Follow this menu selection sequence:

Main Menu Configuration (Load Configuration From)

2.Select the Current, Customer 1, Customer 2, or Default Factory Configuration and press Enter.

The selected configuration option set is loaded and the Configuration Edit/Display menu screen appears.

See Appendix A for a list and explanation of the configuration options available.

Saving Configuration Options

When changes are made to the configuration options, the changes must be saved to take effect. The Save key and Save Configuration To screen appear when the user has an effective access level of 1. All other effective access levels have read-only permission.

"Procedure

To save configuration options changes:

1.Press Ctrl-a to switch to the screen function key area below the dotted line.

2.Select Save and press Enter. The Save Configuration To screen appears.

3.Select one of the three configuration option areas on the screen and press Enter. When Save is complete, Command Complete appears in the message area at the bottom of the screen.

NOTE:

When Exit is selected before Save, a Save Configuration screen appears requiring a Yes or No confirmation response.

If you select . . .

Then the . . .

Yes

No

Save Configuration To screen appears.

Main Menu appears and changes are not saved.

7112-A2-GB20-20