MIB Descriptions

Enterprise MIB Object

The following Paradyne Enterprise MIB Object is supported by the unit:

HDevice Configuration Variable, Table C-17

Device Configuration Variable (pdn-common 7)

The variable devConfigAreaCopy in the devConfigArea group is supported. This variable allows the entire contents of one configuration area to be copied into another configuration area. The unit only supports the following values.

Table C-17. Device Configuration Variable

Object, OID, Access

Description

Setting/Contents

 

 

 

devConfigAreaCopy

A ªgetº of this object will

noOp(1)

1.3.6.1.4.1.1795.2.24.2.7.1.1

always return noOp.

 

 

 

Copy from active area to

active-to-customer1(2)

read-write

 

customer 1 area.

 

 

 

 

 

Copy from active area to

active-to-customer2(3)

 

customer 2 area.

 

 

 

 

 

Copy from customer 1 area

customer1-to-active(4)

 

to active area.

 

 

 

 

 

Copy from customer 1 area

customer1-to-

 

to customer 2 area.

customer2(5)

 

 

 

 

Copy from customer 2 area

customer2-to-active(6)

 

to active area.

 

 

 

 

 

Copy from customer 2 area

customer2-to-

 

to customer 1 area.

customer1(7)

 

 

 

 

Copy from factory area to

factory1-to-active(8)

 

active area. There is only one

 

 

factory area for the unit.

 

 

 

 

 

Copy from factory area to

factory1-to-

 

customer 1 area.

customer1(9)

 

 

 

 

Copy from factory area to

factory1-to-

 

customer 2 area.

customer2(10)

 

 

 

Device Security, pdn-security (pdn-common 8)

Use the Device Security table to control the number of SNMP managers that may access the unit, as well as the unit access level (read or read/write). Fully supported by the unit.

Device Traps, pdn-traps (pdn-common 9)

Controls the SNMP managers to which the unit reports traps. Fully supported by the unit.

Device Control, pdn-control (pdn-common 10)

Uses the devControlReset object to reset the unit. Fully supported by the unit.

7112-A2-GB20-20

March 1998

C-29

Page 131
Image 131
Paradyne 7112 Enterprise MIB Object, Device Configuration Variable pdn-common, Device Security, pdn-security pdn-common