Configuration Option Tables

Ethernet Port Options Menu

For Ethernet Port Options, refer to Table A-5. To access the Ethernet Port

Options screen, follow this menu selection sequence:

Main Menu Configuration Load Configuration From

Edit Ethernet Port

Table A-5. Ethernet Port Options (1 of 2)

Port Use

Possible Settings: 802.3, Version 2, Disable

Default Setting: Version 2

The Ethernet port provides a choice of functions.

802.3± Configures the DSU/CSU to use IEEE 802.3 format.

Version 2 ± Configures the system to use Ethernet Version 2 format.

Disable ± Data received on this port is ignored.

HNo other fields in this table will appear when set to Disable.

IP Address

Possible Settings: 000.000.000.000 ± 255.255.255.255, Clear

Default Setting: 000.000.000.000

Specifies the IP (Internet Protocol) address used to identify the Ethernet port. Each three-digit decimal number represents a byte.

000.000.000.000 ± 255.255.255.255 ± Enter an address. The range for the first byte is 000 to 255, with the exception of 127. The range for the remaining three bytes is 000 to 255.

Clear ± Clears the IP Address and sets to all zeros.

IP Subnet Mask

Possible Settings: 000.000.000.000 ± 255.255.255.255, Clear

Default Setting: 000.000.000.000

Specifies the subnet mask needed to access the Ethernet port.

000.000.000.000 ± 255.255.255.255 ± Set the Ethernet port subnet mask. The range for each byte is 000 to 255.

Clear ± Clears the subnet mask and sets to all zeros. When the subnet mask is all zeros, the device creates a default subnet mask based on the class of IP address:

±Class A defaults to 255.000.000.000

±Class B defaults to 255.255.000.000

±Class C defaults to 255.255.255.000

7112-A2-GB20-20

March 1998

A-11