Testing

7-3

7112-A2-GB20-20 March 1998
Running Network Tests
Network tests require the participation of your network service provider. To
access the Network Tests screen, follow this menu selection sequence:
Main Menu
Test

Network Tests

main/test/network PARADYNE
Device Name: Model: 7112
NETWORK TESTS
Test Command Status Result
Local Loopbacks
Line Loopback: Start Inactive 0:00:00
Payload Loopback: Start Inactive 0:00:00
Repeater Loopback: Start Inactive 0:00:00
Remote Loopbacks
Send Line Loopback: Up Send Inactive 0:00:00
Pattern Tests
Send: QRSS Start Active 0:00:00
Monitor: QRSS Start Active 99:08:48 – Errors 99999+
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Ctrl-a to access these functions, ESC for previous menu MainMenu Exit
Use the Command column to start or stop a test by pressing Enter. The Result
column displays the test duration since the last device reset. When the Monitor
QRSS test is active, ResetMon is available to reset the error counter to zero.
Selecting the Stop command on the Network Test screen or Abort Tests from the
Test menu will not disrupt a network-initiated loopback.