Paradyne 7112 manual ± Starts a Monitor 511 test on the interface

Models: 7112

1 156
Download 156 pages 11.03 Kb
Page 129
Image 129

MIB Descriptions

Table C-16. Generic Interface Test Table Objects (2 of 3)

Object

Description

Setting/Contents

ifExtnsTestType (cont'd)

The following objects use identifiers to control tests only on the User Data port interface:

HtestFullDuplexLoopBack (wellKnownTests 1) ± Starts a Data Channel Loopback (DCLB) on the interface.

HtestLoopDTLB (wellKnownTests 2) ± Starts a Data Terminal Loopback (DTLB) on the interface.

HtestMon 511 (wellKnownTests 4)

± Starts a Monitor 511 test on the interface.

HtestSendQRSS (wellKnownTests 5) ± Starts a Send QRSS test on the interface.

HtestSend511 (wellKnownTests 6) ± Starts a Send 511 test on the interface.

HtestSendV54Up (wellKnownTests 7) ± Sends a V.54 up code to the remote unit.

HtestSendV54Down (wellKnownTests 8) ± Sends a V.54 down code to the remote unit.

HtestSendFT1Up (wellKnownTests 9) ± Sends a FTI up code to the remote unit.

HtestSendFT1Down (wellKnownTests 10) ± Sends a FT1 down code to the remote unit.

7112-A2-GB20-20

March 1998

C-27

Page 129
Image 129
Paradyne 7112 manual ± Starts a Monitor 511 test on the interface