4. Troubleshooting

1000-A2-GN22-00

 

 

Table 4–5. MP Module Troubleshooting

Symptom

Probable Causes

Corrective Action

 

 

 

PWR indicator is

CPX is not powered

Verify that the CPX is receiving –48 VDC from

off.

up.

the plant battery.

 

 

 

 

MP module did not

Turn CPX rear circuit breaker off, then on

 

initialize properly

again to cycle power and reinitialize.

 

upon CPX power-up.

 

 

 

 

 

MP module is faulty.

Ensure CP modules are initialized to bring

 

 

power to MP card.

 

 

Replace module (Hot Swapping an MP Card

 

 

on page 5-10).

 

 

 

Ethernet green

MP-to-LAN interface is

Troubleshoot LAN (Table 4–8 on page 4-11).

indicator is off.

faulty.

 

 

 

 

Note

The Splitter Assembly is part of the STS system. The Splitter Assembly provides card redundancy by splitting receive and transmit signal to two STS cards. The active STS card receive and transmits signal. The standby card only receives signal.

The Splitter Assembly is shipped with BNC terminators in place to prevent signal degradation. The terminators should be left in place until an STS cable is connected, and should be replaced if the cable is removed.

When pulling cables on STS systems, disconnect the cable at the splitter end first, and immediately install a terminator. Then, disconnect the cable at the STS card end. When reconnecting, connect the cable at the splitter end first. Then, remove the terminator at the splitter assembly and immediately connect the STS cable.

The BNC terminators should also be used if the Splitter Assembly is used in a non-redundant environment. For example, customers who order the splitter assembly with the intent to upgrade later to redundancy should keep the terminators in

place.