Paradyne CPX-1000 manual Voice/Data Interruptionœ possible

Models: CPX-1000

1 160
Download 160 pages 36.84 Kb
Page 40
Image 40
Administrative switchover—the network administrator initiates a CP switchover using JetCraft or JetVision. A forced switchover always goes through regardless of voice traffic and active cells remain up.

2. CPX-1000 Voice Services Platform Description

1000-A2-GN22-00

 

 

This architecture enables two types of CP module switchovers:

￿

Automatic switchover—the system detects a problem

with the active CP module and performs a forced

switchover to the standby CP module. Mechanisms used to

detect problems with a CP module include:

— Loss of a CP-to-MP (Management Processor) module

heartbeat

— Loss of a CP-to-CP module heartbeat

— Failure of a CP to respond to an “are you alive” ping

request from the High Availability software

 

— Failure of the High Availability software to detect a ping

 

request from the ping component on a CP module

Voice/Data￿ Interruptionœ – possible

Calls that are in setup process are lost during a forced switchover. Calls that are already established and carrying voice traffic continue during a switchover.

Upon initiating a switchover, the previously active CP’s calls are assumed by the new active CP. After the switchover, the old active CP assumes the standby role (if all is well). CP switchovers do not automatically revert back.

2-16

February 2003

Page 40
Image 40
Paradyne CPX-1000 manual Voice/Data Interruptionœ possible