3. Installing the CPX-1000

1000-A2-GN22-00

 

 

23" Rack

Mounting Ear faces away from shelf

19" Rack

Attaching Cables to 12-Port T1 Modules

Mounting Ear faces in toward shelf

0188

The 12-port T1 card provides an RJ-21X port to which you connect

acustomer-supplied 25-pair cable (Paradyne part number 035- 0446-1030) with an RJ-21X jack at one end. The other end is connected to a punchdown block to separate each T1 circuit on the RJ-48C patch panel, or directly to the Class 5 switch.

Steps for connecting the RJ-21X cable to a patch panel are described below. For completing the connection of the T1 circuits from the Class 5 switch to the patch panel, see Attaching Cables to Octal T1 Modules, above.

Cabling requirements for your installation may be different.