4. Troubleshooting

1000-A2-GN22-00

 

 

Power System Troubleshooting

The CPX requires 48V power from a plant battery source. Two 48Vdc inputs (A and B) are wired to the CPX, so that if one input

to the system fails, the other maintains power. Input A delivers power to the left and center power supply modules; Input B delivers power to the center and right power supply modules.

The CPX has three load-sharing power supplies, which deliver dc voltage to all of the plug-in modules. A circuit breaker located on the CPX rear panel, provides equipment electrical protection (Figure 4–2).

Open Protective Guards

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

DC -48V

 

 

 

 

 

 

 

 

 

 

DC -48V

 

 

 

DC -48V

 

 

 

 

 

 

 

 

 

 

DC -48V

 

 

 

RTN

 

 

 

 

 

 

 

 

 

 

RTN

 

 

 

 

-48V RTN -48V

To

Plant Battery "A"

Frame

Plant

Circuit

Ground

Battery A

Breaker

Points

Barrier Strip

 

(requires

 

 

10-32 x 1/4"

 

 

screws)

 

 

0069

Plant

- -

48V

48V

Battery B

RTN

 

Barrier Strip

 

 

 

To

Plant Battery "B"

 

Figure 4–2. Power Panel and Circuit Breaker

 

After you apply power to the CPX, if none of its front panel

 

indicators light, and if its internal fans are not working, refer to

 

Table 4–9for troubleshooting instructions.

 

Isolate a problem to one or more modules before troubleshooting:

Step 1

After applying power, wait at least two minutes for the system to

 

initialize. If none of its front panel indicators light and its internal

 

fans are off, see Troubleshooting Instructions (Table 4–9).