1000-A2-GN22-00

4. Troubleshooting

 

 

Table 4–6. PSTN Module Troubleshooting (Continued)

Symptom

Probable Causes

Corrective Action

 

 

 

Secondary EOC PPS

CPX and Class 5 switch

Verify that the interface group is active

Link is down

connection has been lost.

in the switch.

 

 

 

Receive data on inactive

Switch and CPX do not

Have the switch force a PPS switch on

link

agree on which link is

the TMC or EOC link.

 

active on TMC or EOC.

 

 

 

 

Table 4–7. ATM Module Troubleshooting

Symptom

Tx and/or Rx indicators are off.

Probable Causes

Corrective Action

Software error occurred

1. Turn the CPX-1000 rear circuit

on the CP module,

breaker switch off, then on again.

causing the ATM module

2. After the system initializes, verify

to initialize improperly.

that the ATM module Tx and/or Rx

 

 

indicators are lit or flashing.

 

 

ATM module is faulty.

Replace the ATM module (see Module

 

Troubleshooting on page 4-6).

 

 

Table 4–8. Ethernet LAN Troubleshooting

Symptom

Probable Causes

Corrective Action

 

 

 

Ethernet link (green)

The MP module is not

Connect the Ethernet jack of the MP

indicator is not lit.

connected to the LAN.

Transition card to the LAN.

 

 

 

 

The LAN is down.

Problem is in the LAN, external to the

 

 

CPX. Contact the LAN administrator

 

 

to determine cause.

 

 

 

 

Faulty cable between CPX

Replace the cable between the MP

 

and another LAN device.

Transition card and the LAN device

 

 

with an identical cable.

 

 

 

 

The MP module is faulty.

Replace the card (see Hot Swapping

 

 

an MP Card on page 5-10)

 

 

 

CPX ping test failed

Same as for abnormal MP,

Take the corrective actions described

(unable to ping CPX

XMT, and RCV indicator

above.

from a PC on the LAN).

states listed in this table.

 

 

 

 

February 2003

4-11

Page 111
Image 111