1000-A2-GN22-00

D. Specifications

 

 

Table D–2. CPX-1000 Environmental Specifications

Parameter

 

Specification

 

 

 

Reference

 

 

 

 

 

 

 

Operating temperature

 

5 C to 40 C (40 F to 104 F)

 

GR-63-CORE, R4-6, R4-7

 

Operating humidity

 

5% to 85% RH, non-condensing

GR-63-CORE, R4-6, R4-7

 

Storage and transit temperature

–40

°

C to +70 C (–40 F to 158 F)

GR-63-CORE, R4-3, R4-4

 

Storage and transit humidity

 

 

°

°

 

°

GR-63-CORE, R4-5

 

 

95% RH at 40 C (104 F)

 

 

 

Altitude

 

 

 

 

 

 

 

 

 

without temperature derating

60m to 1800m above sea level

GR-63-CORE, R4-8

 

 

 

 

 

 

°

 

 

 

 

 

°200 ft to°5905°ft)

 

 

 

 

with temperature derating

 

(−

 

 

 

 

 

GR-63-CORE, R4-9, O4-

 

 

1800 to 4000m above sea level

 

 

 

(5095 ft to 13,123 ft)

 

 

 

10

 

Airborne contaminant

 

25 ppi pore size, 63% dust

 

GR-63-CORE, 4.5, R4-59,

 

 

 

arrest. UL-900°Class V°-2, UL 94

O4-60

 

 

 

H-1 flammability rated

 

 

 

 

 

 

 

 

 

 

 

 

Table D–3. CPX-1000 Electrical Specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Specification

 

 

 

Reference/Comment

 

 

 

 

 

 

 

 

 

 

 

Electrical safety criteria

 

 

 

 

 

 

 

GR-1089-CORE,

 

 

 

 

 

 

 

 

 

Section 7.0

 

Bonding and grounding

Common, integrated ground plane,

GR-1089-CORE,

 

 

multi-point ground

 

 

 

Section 9.0

 

Input voltage range

–40 VDC to –72 VDC A and B input

 

 

 

 

 

 

 

 

 

 

 

 

Corrosion

 

 

 

 

 

 

 

GR-1089-CORE,

 

 

 

 

 

 

 

 

 

Section 8.0

 

 

 

 

 

 

 

 

 

 

 

February 2003

D-3

Page 151
Image 151
Paradyne manual Table D-2. CPX-1000 Environmental Specifications, Table D-3. CPX-1000 Electrical Specifications