1000-A2-GN22-00

D. Specifications

 

 

Table D–5. CPX-1000 Operating Specifications

Parameter

Specification

Reference

 

 

 

Shock (Category A)

 

 

Packaged

450 mm (18 in.) drop height

GR-63-CORE, R4-41

Unpacked

25 mm (1 in.) drop height

GR-63-CORE, R4-43

 

 

 

Earthquake

Zone 4

GR-63-CORE, 4.4.1, R4-44

 

 

to O4-55

 

 

 

Vibration - Office

0.1g @ 5 to 100 Hz with 0.1 Octave/min.

GR-63-CORE, R4-56, R4-57

In Transit

3 axis, Curve 1

GR-63-CORE, R4-58

Maximum BTU

1720 BTU/hour

 

Heat dissipation

300W/m sq., per meter of frame height

GR-63-CORE, O4-13

(forced air)

used

GR-63-CORE, O4-12,

 

38 C (86 F) max. aisle-facing surface @

 

O4-13

 

26°C (80°F ambient temperature

 

 

Fire resistance

)

GR-63-CORE, 4.2, R4-14 to

All material meets ANSI

 

T1.307-1990 set 4.2 and UL94V-1 or better

O4-40

Electromagnetic

 

GR-1089-CORE, Section

Interference

 

3.0

 

 

 

Table D–6. STS-1 Splitter Assembly Physical Specifications

Parameter

Dimensions:

Weight

Specification

3.5” high

17.2” wide (19” with mounting flanges)

3” deep

2 lbs

×

×