1000-A2-GN22-00

2. CPX-1000 Voice Services Platform Description

 

 

Table 2–1. Alarm Indicator Status and Description

Alarm Indicator

Slot Status

System Status

Telco Status

Status

Act

Unlocked

Disabled

Alert A

Alert B

Alert C

Minor

Major

Critical

Description

Module is in Active state (not Standby)

Module administrative state is Unlocked

Module operational state is Disabled

Not used

Not used

Not used

CPX minor alarm

CPX major alarm

CPX critical alarm

The three Telco alarms and a rack alarm are also routed through a dry contact relay to the RJ-45 remote alarm connector.

The standard Telco alarm signals and rack alarm are available as an output to remote alarm equipment (Table 2–2).

Table 2–2. Remote Alarm Connector

Pin

1

2

3

4

5

6

7

8

Signal

Critical Alarm Critical Alarm Return Major Alarm Major Alarm Return Minor Alarm Minor Alarm Return Rack Alarm (not used)

Rack Alarm Return (not used)

February 2003

2-11

Page 35
Image 35
Paradyne CPX-1000 Alarm Indicator Status and Description, Slot Status System Status Telco Status, Remote Alarm Connector