Paradyne CPX-1000 Attach Ethernet Cables, Attach CP Redundancy Cable, Attach MP Card to CP Cards

Models: CPX-1000

1 160
Download 160 pages 36.84 Kb
Page 89
Image 89

1000-A2-GN22-00

3. Installing the CPX-1000

 

 

Attach

Ethernet

Cables

Connect the MP module to the CP modules via Ethernet. You can also connect the CPX shelf to an Ethernet LAN for access via remote system management.

Attach CP Redundancy cables here

Management

Call

 

ATM OC-3

Processor

Processor

12-Port T1

Port T1 Module

Module Sets ECAC

Modules

ECAC

 

 

Modules

 

 

 

 

 

 

Attach CPX to LAN here

TDM-12E1/T1

TDM-12E1/T1

TDM-12E1/T1

TDM-12E1/T1

TDM-12E1/T1

 

 

 

 

CP2

 

 

CP2

TDM-12E1/T1

TDM-12E1/T1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PCI

 

 

 

PCI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MEZZANINE

LNK

ACT

PWR

MEZZANINE

LNK

ACT

PWR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M

2

 

ERROR

2

 

ERROR

 

 

 

 

 

 

 

Attach

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

CARD

 

 

 

CARD

 

 

 

 

 

 

Status

Status

Status

Status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tx

Tx

Tx

Tx

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LNK

ACT

 

 

LNK

ACT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10/100

 

 

 

10/100

 

 

 

 

 

Rx

Rx

Rx

Rx

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ETHERNET

 

 

ETHERNET

 

 

 

 

 

 

 

 

MP to CP

 

 

 

 

 

 

 

 

 

 

 

1

 

10/100 BASE T

 

 

 

10/100 BASE T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LNK

ACT

 

COM 1

 

 

 

COM 1

 

 

 

 

 

 

 

 

 

 

cables here

S

A

S

A

S

A

S

A

S

A

 

 

P

 

 

 

 

 

S

A

S

A

 

 

 

 

T

T

T

T

T

 

 

M

 

 

 

 

 

 

 

T

T

 

 

 

 

A

C

A

C

A

C

A

C

A

C

 

 

 

 

 

 

 

 

 

A

C

A

C

 

 

 

 

T

T

T

T

T

T

T

T

T

T

 

2

C

 

 

 

 

 

 

 

T

T

T

T

 

 

 

 

1

2

1

2

1

2

1

2

1

2

 

1

 

 

 

 

 

 

 

1

2

1

2

 

 

 

 

3

4

3

4

3

4

3

4

3

4

 

 

 

 

 

 

 

 

 

 

3

4

3

4

 

 

 

 

 

5

6

5

6

5

6

5

6

5

6

LNK

ACT

 

 

RST

 

 

 

RST

 

5

6

5

6

 

 

 

 

 

7

8

7

8

 

8

7

8

7

8

10/100

 

 

 

 

 

 

 

 

7

8

7

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ETHERNET

 

 

ABT

 

 

 

ABT

 

 

 

 

 

ATM 155

ATM 155

ATM 155

ATM 155

 

9

10

9

10

9

10

9

10

9

10

 

 

 

 

 

 

 

 

 

 

9

10

9

10

 

11

12

11

12

11

12

11

12

11

12

ETHERNET

 

 

 

BFL

CPU

 

 

BFL

CPU

11

12

11

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CPCI

PCI

 

 

CPCI

PCI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COM 1

 

 

USB 1

 

 

 

USB 1

 

 

 

 

 

 

 

 

 

 

 

HOT

 

HOT

 

HOT

 

HOT

 

HOT

 

RESET

USB 0

 

 

 

USB 0

 

 

HOT

HOT

 

 

 

 

 

 

SWAP

 

SWAP

 

SWAP

 

SWAP

 

SWAP

 

EXT

PWR

 

 

 

 

 

 

SWAP

SWAP

 

 

 

 

 

 

 

1

2

 

3

 

4

 

5

 

6

 

 

7

8

 

9

10

11

12

 

13

14

15

16

 

Attach MP Card to CP Cards

Step 1

Connect the CPX to the LAN

Step 1

Step 2

Attach CP

Redundancy

Cable

To establish a communication link on a shelf with either a T1 or STS-1 configuration:

Connect the Ethernet ports on the MP module (at the front shelf) to the Ethernet ports on the CP A and the CP B card respectively, using the cables provided (Octal T1 card shown).

To connect the CPX to an Ethernet LAN:

Plug a CAT-5 straight-through cable into the RJ-45 Ethernet port of the Management Processor (MP) Transition card.

Connect the other end of the cable to the LAN hub or router

To establish redundancy on the CPX with either a T1 (Octal or 12-port) or STS-1 (without ECAC, or STS-1 with ECAC) configuration, connect the two CP cards (at the front shelf) using the cable provided.

February 2003

3-25

Page 89
Image 89
Paradyne CPX-1000 manual Attach Ethernet Cables, Attach CP Redundancy Cable, Attach MP Card to CP Cards