5. Repair Procedures

1000-A2-GN22-00

 

 

Power Supply/

Fan Module

Removal

Step 1

Each CPX is equipped with 3 power supply/fan modules. Removing a single power supply does not interrupt system operation. To remove a power supply/fan module, see Figure 5–1and follow these steps:

Loosen the two screws located at the bottom of the module.

OUT OF

OUT OF

 

SERVICE

SERVICE

 

IN

IN

 

SERVICE

SERVICE

 

 

 

OSEURTVOICFE

 

 

IN

 

 

SERVICE

Lift Out Filter

Remove 4 Screws

Pull To Remove Fan

 

 

0178

Figure 5–1. Power Supply/Fan Module Removal

 

 

 

 

 

Danger: Shock Hazard

 

 

 

 

 

The CPX uses 48VDC plant battery for primary power. This

 

 

 

 

 

circuit can supply a level of current that can be fatal.

 

 

 

 

 

 

 

 

 

Use extreme caution when working around this voltage,

 

 

 

 

 

during installation, operation, testing, and adjusting.

 

 

 

 

 

Remove the voltage at its point of distribution to the CPX

 

 

 

 

 

before you connect or disconnect equipment power leads.

 

 

 

 

 

 

 

 

 

 

 

Step 2

 

Grip the handle on the front of the module, and slowly pull it

 

 

 

 

 

straight out ofthe chassis. Support the module from the bottom,

 

 

 

 

 

and lift the back edge of it over the front lip of the chassis.

 

 

 

 

 

 

 

Replacing

 

If a fan in a power supply/fan module has failed, replace the

Inoperative

 

affected fan assembly (Figure 5–1).

Fans

 

To replace (hot swap) a fan without removing the module or

 

 

 

 

 

turning off power:

 

Step 1

 

Remove the filter from the power supply to expose four screws.

 

Step 2

 

Loosen the four screws that attach the fan to the power supply.

 

Step 3

 

Pull the handle of the power supply straight out.

5-2

February 2003

Page 116
Image 116
Paradyne CPX-1000 manual Power Supply Fan Module Removal, Replacing, Inoperative, Fans