B. Pin Assignments and Indicators

1000-A2-GN22-00

 

 

Table B–1. Connection Requirements and Physical Layer

Specifications (Continued)

Connections

Cables, Connectors, and Specifications

 

 

 

Ethernet LAN

Physical interface:

CAT-5 or equivalent cable

(10Base-T or 100Base-T)

Termination:

RJ-45 plug

 

 

 

Bonding network environment

Common, integrated ground plane, multi-point ground.

 

 

–48 VDC plant battery and return

Minimum 14 AWG wires (total of four), stranded or

 

solid; up to 40 feet maximum from the plant battery

 

distribution point.

 

 

Terminate using LCC or LCD compression lugs (with

 

two #10 screw holes).

 

Range: 40 VDC to

72 VDC

 

Turn On: 38.5V to 41V

 

Turn On surge current: 40A (with two power supplies

 

installed) at 40 VDC, for duration <4 ms

 

 

Frame ground

Stranded copper wire; must be larger than the wire size

 

used for –48V power and ground wiring (6 AWG

 

recommended). This cable must be fitted with a Type

 

LCC or LCD dual-lug compression connector on one

 

Allend,connectionsforattachmentmusttobethetinCPX-coated-1000coppershelf.crimp lugs.

Alarm output connections

22-gauge solid wire for dry contact closures to an

 

external alarmmonitoring system.

Table B–2. Ethernet LAN Jack Pin Assignments

Pin

1

2

3

4

Signal

 

Pin

Tx (+) to LAN

 

 

5

Tx ( ) to LAN

 

6

Rx (+) from LAN

 

7

Notconnected

 

8

 

 

Signal

Not connected

Rx ( ) from LAN Notconnected Not connected

B-4

February 2003

Page 142
Image 142
Paradyne CPX-1000 manual Table B-2. Ethernet LAN Jack Pin Assignments, Tx + to LAN Tx to LAN Rx + from LAN, Not connected