1000-A2-GN22-00

4. Troubleshooting

 

 

 

Note

 

The CPX may take several minutes to initialize,

 

depending on the number of PSTN and ATM modules.

 

 

 

Step 2

Check the CPX plug-in module indicators to verify that they are

 

operating correctly. If any indicator states are incorrect, identify the

 

module type and refer to the appropriate table for action.

Table 4–9. Power Failure Troubleshooting

Symptom

Probable Causes

Corrective Action

 

 

 

All CPX plug-in

A power surge tripped the

Turn the circuit breaker on to apply

module indicators are

CPX circuit breaker.

power to the CPX.

off.

 

 

Faulty –48 Vdc output

1. Check the -48 Vdc and battery

 

 

wiring, from the plant

return connections between the

 

battery distribution point

power source and CPX A and B

 

to the CPX.

terminals (see Figure 4–2).

 

 

2. Replace faulty wiring as required.

 

 

 

 

-48 VDC plant battery

1. Verify that the -48VDC plant battery

 

source is faulty.

has the correct polarity.

 

 

2. Measure the plant battery voltage at

 

 

the power distribution point

 

 

(–42 VDC to –56 VDC).

 

 

 

Out Of Service power

Power supply module is

Replace the module (see Install Power

supply module

faulty.

Supply/Fan Module on page 5-3).

indicator is lit.

 

 

 

 

 

None of the Power

CPX is not powered up.

Perform system power failure

Supply module

 

troubleshooting.

indicators are lit.

 

 

 

 

 

Cooling failure on one

Fan failure or jammed fan

Replace the power supply.

power supply.

shutter.

 

 

 

 

Cooling failure for

Airflow blockage.

1. Check air inlets and outlets for

more than one power

 

obstructions.

supply.

 

2. Clean or replace the air filters.

 

 

 

 

 

 

Excessive ambient air

Reduce the room air temperature.

 

temperature.

 

 

 

 

February 2003

4-13

Page 113
Image 113
Paradyne CPX-1000 manual CPX may take several minutes to initialize, Depending on the number of Pstn and ATM modules