3. Installing the CPX-1000

1000-A2-GN22-00

 

 

Step 9

Echo Cancellation Indicators: Verify that the Hot Swap

 

indicator is not lit. The STATUS indicator lights yellow when the

 

CPX is using the module.

Step 10

Echo Cancellation and Compression Module Indicators:

Alarm Panel Indicators

Verify that the Hot Swap indicator is not lit. The STATUS indicator lights yellow when the CPX is using the module.

Check the Alarm panel indicators:

 

Step 1

Verify that the APP indicator flashes on and off continuously

 

 

(one second on, one second off).

 

Step 2

Verify that all of the system status indicators are off (they are

 

 

not used).

 

 

 

Check the Fans

The two CPX Power Supply Fan modules are equipped with an

 

 

integral fan assembly, and a third fan is supplied for redundancy

 

 

(in case one of the other two fans fails).

Step 1

Step 2

Verify Remote Interface

Connect JetCraft PC to CPX-1000

Change CPX

Default IP

Address

When power is first applied, the fans should run continuously, circulating air through the system’s plug-in modules.

Verify that the fans are running, and that the front vents on the power supplies and the shelf rear vents are free of obstruction.

The CPX requires a remote connection for remote management. To verify the remote port operation after powering up the CPX, perform these tasks:

Make sure that JetCraft is installed on a PC. Connect the PC directly to the ETHERNET 1 port on the MP transition card.

For this connection, use a CAT-5 crossover cable with RJ-45 plugs.

The default IP address for the CPX is:

IP address

10.0.10.100

subnet mask

255.255.0.0

3-34

February 2003

Page 98