1000-A2-GN22-00

5. Repair Procedures

 

 

Step 2

Step 3

Step 4

Module

Removal and

Installation

Caution

If the panel does not fully insert, do not force it—forcing it can bend the connector pins. Instead, back the panel out, verify that the connectors are aligned properly, and re-insert it.

Tighten the four captive screws in the corners of the panel.

Replace the power cable.

Turn on the CPX.

Use this procedure to replace a CPX plug-in module by removing it from the shelf and installing another module.

The cards must first be removed from service using a network management system (JetCraft or JetVision).

Review and perform the steps in Hot Swapping on page 5-10.

CAUTION

CLASS 1 LASER

Use of controls, adjustment, or performance of procedures other than those specified herein may result in hazardous, invisible radiation exposure.

Module panel indicators are Class 1 LED products.

Warning

Some CPX components include field-replaceable batteries. A new battery can explode if incorrectly installed. Replace the battery only with the same or equivalent type recommended by the manufacturer. Discard batteries according to the manufacturer's instructions.

February 2003

5-7