Paradyne CPX-1000 manual Pstn Module Troubleshooting, Verify that the CPX is receiving

Models: CPX-1000

1 160
Download 160 pages 36.84 Kb
Page 109
Image 109

1000-A2-GN22-00

4. Troubleshooting

 

 

Table 4–6. PSTN Module Troubleshooting

Symptom

Probable Causes

Corrective Action

 

 

 

No indicators are lit on

CPX is not powered.

Put the suspect card on standby,

the T1/STS-1 module.

 

locked, resources removed. Then

 

 

switch it out (see Hot Swapping Line

 

 

Cards on page 5-11)

 

 

Verify that the CPX is receiving –48

 

 

VDC from the plant battery.

 

 

 

 

Software error occurred

Power down the CPX, then reapply

 

on the CP module,

power by turning its circuit breaker

 

preventing the T1/STS-1

switch off, then on again

 

module from initializing.

(see Figure 4–2on page 4-12).

 

 

 

 

T1/STS-1 module is

Replace the module (see Module

 

faulty.

Troubleshooting on page 4-6)

 

 

 

FAIL indicators are lit

Software error occurred

1. Turn the CPX rear circuit breaker

and/or RUN indicators

on the CP module,

switch off, then on again.

are off on all T1

causing the T1 modules to

2. After the system initializes, verify

modules in the CPX.

initialize improperly.

that all T1 module FAIL indicators

 

 

 

 

are off and RUN indicators are lit.

 

 

 

 

CP module is faulty.

Switch over CP to standby. If required,

 

 

swap out (see Hot Swapping CP and

 

 

HSC Cards on page 5-11)

 

 

 

FAIL indicator is lit and/

T1 module is faulty.

Replace the module (see Module

or RUN indicator is off

 

Troubleshooting on page 4-6).

on a single T1 module;

 

 

Software error occurred

1. Turn the CPX rear circuit breaker

all other T1 modules

show normal FAIL and

on the CP module,

switch off, then on again.

RUN indicator states.

causing the T1 module to

2. After the system initializes, verify

 

initialize improperly.

that the T1 module FAIL indicator is

 

 

 

 

off and the RUN indicator is lit.

 

 

 

Tx and/or Rx indicators

Software error occurred

1. Turn the CPX rear circuit breaker

on the STS-1 card are

on the CP module,

switch off, then on again.

off.

causing the STS-1 module

2. After the system initializes, verify

 

to initialize improperly.

 

that the STS-1 module Tx and/or Rx

 

 

 

 

indicators are lit or flashing .

 

 

 

 

STS-1 module is faulty.

Replace the STS-1 module (see

 

 

Module Troubleshooting on page 4-6).

 

 

 

February 2003

4-9

Page 109
Image 109
Paradyne CPX-1000 manual Pstn Module Troubleshooting, Verify that the CPX is receiving, VDC from the plant battery