Command Line Interface (CLI)

AP-700 User Guide

Parameter Tables

 

 

 

System Parameters

 

Name

Type

Value

Access

CLI Parameter

 

System

Group

N/A

R

system

 

Name

DisplayString

User Defined

RW

sysname

 

Location

DisplayString

User Defined

RW

sysloc

 

Contact Name

DisplayString

User Defined

RW

sysctname

 

Contact E-mail

DisplayString

User Defined

RW

sysctemail

 

Contact Phone

DisplayString

User Defined

RW

sysctphone

 

 

 

max 254 characters

 

 

 

FLASH Backup Interval

Integer

0 - 65535 seconds

RW

sysflashbckint

 

Flash Update

 

0

RW

sysflashupdate

 

 

 

1

 

 

 

System OID

DisplayString

N/A

R

sysoid

 

Descriptor

DisplayString

System Name, flash

R

sysdescr

 

 

 

version, S/N, bootloader

 

 

 

 

 

version

 

 

 

Up Time

Integer

dd:hh:mm:ss

R

sysuptime

 

 

 

dd - days

 

 

 

 

 

hh - hours

 

 

 

 

 

mm - minutes

 

 

 

 

 

ss - seconds

 

 

 

Emergency Restore to

 

Resets all parameters to

RW

sysresettodefaults

 

defaults

 

default factory values

 

Note: You must enter the

 

 

 

 

 

following command twice to

 

 

 

 

 

reset to defaults:

 

 

 

 

 

set sysresettodefaults 1

Inventory Management Information

 

 

 

 

 

 

 

 

 

 

Name

Type

Value

Access

CLI Parameter

 

System Inventory

Subgroup

N/A

R

sysinvmgmt

 

Management

 

 

 

 

 

Component Table

Subgroup

N/A

R

sysinvmgmtcmptbl

 

Component Interface

Subgroup

N/A

R

sysinvmgmtcmpiftbl

 

Table

 

 

 

 

NOTE: The inventory management commands display advanced information about the AP’s installed components. You may be asked to report this information to a representative if you contact customer support.

176

Page 176
Image 176
Proxim AP-700 manual System Parameters, Name Type Value Access CLI Parameter, Set sysresettodefaults, 176