Monitoring |
|
Interfaces
Interfaces
This tab displays statistics for the Ethernet and wireless interfaces.
Figure 5-8 Interface Monitoring Tab (Ethernet)
Description of Interface Statistics
The following statistics are displayed for the Ethernet interface only, the wireless interface only, or for both the Ethernet and wireless interfaces:
•Admin Status (Ethernet/Wireless): The desired state of the interface: Up (ready to pass packets), Down (not ready to pass packets, or Testing (testing and unable to pass packets).
•Alignment Error (Ethernet): The number of frames received that are not an integral number of octets in length and do not pass the Frame Check Sequence check.
•Carrier Sense Errors (Ethernet): The number of times that the carrier sense condition was lost or never asserted when attempting to transmit a frame. The count increments at most once per transmission attempt.
•Deferred Transmission (Ethernet): The number of frames for which the first transmission attempt is delayed because the medium is busy.This number does not include frames involved in collisions.
•Description (Ethernet/Wireless): Information about the interface (e.g., the name of the manufacturer, the product name and the version of the hardware interface).