Proxim AP-700 manual Click Configure Alarms Rogue Scan

Models: AP-700

1 221
Download 221 pages 11.69 Kb
Page 85
Image 85

Advanced Configuration

AP-700 User Guide

Alarms

 

 

 

Channel: the working channel of the detected station

SNR: the SNR value of the last frame from the station as received by the AP

BSSID: the BSSID field stores the:

MAC address of the associated Access Point in the case of a client.

Zero MAC address or MAC address of the partner Access Point if the AP is a partner of a WDS link

The AP ages out older entries in the Rogue Scan result table if a detected station is inactive for more than the Scan Result Table Ageing Time.

Rogue Scan

Perform this procedure to enable Rogue Scan and define the Scan Interval. See Figure 4-26 on page 86.

The Rogue Scan screen also displays the number of new access points and clients detected in the last scan on each wireless interface.

1.Enable the Security Alarm Group. Select the Security Alarm Group link from the Rogue Scan screen. Configure a Trap Host to receive the list of access points (and clients) detected during the scan.

2.Click Configure > Alarms > Rogue Scan.

3.Enable Rogue Scan on the wireless interface by checking Enable Rogue Scan.

NOTE: Rogue Scan cannot be enabled on a wireless interface when the Wireless Service Status on that interface is shutdown. First, resume service on the wireless interface.

4.Enter the Scan Mode. Select Background Scanning or Continuous Scanning. In Continuous Scanning mode the AP stops normal operation and scans continuously on that interface. In Background Scanning mode, the AP performs background scanning while doing normal AP operation on that interface.

5.If the Scan Mode is Background Scanning, then enter the Scan Interval.

The Scan Interval specifies the time period in minutes between scans in Background Scanning mode and can be set to any value between 1 and 1440 minutes.

6.Configure the Scan Result Table Ageing Time. The AP ages out older entries in the Rogue Scan result table if a detected station is inactive for more than this time. The valid range is from 60-7200 minutes, the default is 60 minutes.

7.Configure the Scan Results Trap Notification Mode to control the notification behavior when APs or stations are detected in a scan:

No Notification

Notify AP

Notify Client

Notify All (Notify both AP and Client detection)

8.Configure the Scan Results Trap Report Style to control the way detected stations are reported in the notification:

Report all detected stations since last scan (default)

Report all detected stations since start of scan

9.Click OK.

The results of the Rogue Scan can be viewed in the Status page in the HTTP interface.