A

C – Log Messages Error Log Messages

Table C-6. Fibre Channel Driver—Error Log Messages (Continued)

ID

Log Messages

No.

 

 

 

106813

#%d: QLIsrEventHandler: Unexpected async event (%x),

317

 

MB1=%x, MB2=%x, MB3=%x, MB4=%x, MB5=%x, MB6=%x,

 

 

MB7=%x

 

 

 

 

106853

#%d: QLTimer: Link error count (0x%x) exceeded, link down

357

 

 

 

106912

#%d: QLReserveLoopId: out of loop Ids

416

 

 

 

106928

#%d: QLMarkDeviceOffline: Device Id: %x marked offline,

432

 

cLinkDownTimeout = %x, cPortDownRetryCount=%x

 

 

 

 

106948

#%d: QLSnsGetAllNext: Name server login FAILED %x

452

 

 

 

107029

#%d: QLUpdateDeviceData: out of slots in host database

533

 

 

 

107030

#%d: QLUpdateDeviceData: out of slots in target database

534

 

 

 

107041

#%d: QLUpdateDeviceDatabase 0x%x: GET_ID failed %x

545

 

 

 

107056

#%d: QLUpdateDeviceDatabase 0x%x: out of slots in host data-

560

 

base

 

 

 

 

107078

#%d: QLUpdatePort 0x%x: out of slots in host database

582

 

 

 

87The FC processor received a SCSI command for an unknown target path or has run out of resources to execute additional commands.

93The FC processor was disabled by an IOCTL request to the driver.

94The FC processor firmware failed initialization. The request to initialize was received by the driver in an IOCTL request.

96The FC processor failed the external loopback test.

97The FC processor failed to re-initialize in response to an IOCTL disable request.

307 The FC processor reported a link down condition.

317The FC processor reported an unexpected asynchronous event. The mail- box registers provide status, event code, and data related to the event.

357The driver has determined that the FC link is unreliable and unusable due to the number of errors encountered. The link has been taken down.

416The FC processor was unable to obtain the number of loop IDs required. This failure occurs only when the FC processor is running multi-ID firmware.

432The driver was unable to re-establish connection to the target within the tim- eout and retry counts, and is therefore marking it offline.

FI0154601-00 C

C-11

Page 219
Image 219