MIDI Implementation

Program Change

Status

2nd byte

 

CnH

ppH

 

n = MIDI channel number:

0H - FH (ch.1 - 16)

pp = Program number:

00H - 7FH (prog.1 - prog.128)

*These messages are transmitted when Patch is selected. But not transmitted when Transmit Program Change parameter (SYSTEM Com MIDI/USB) is OFF.

Channel Pressure

Status

2nd byte

 

DnH

vvH

 

n = MIDI channel number:

0H - FH (ch.1 - 16)

vv = Channel Pressure:

00H - 7FH (0 - 127)

Pitch Bend Change

Status

2nd byte

3rd byte

EnH

llH

mmH

n = MIDI channel number:

0H - FH (ch.1 - 16)

mm, ll = Pitch Bend value:

00 00H - 40 00H - 7F 7FH (-8192 - 0 - +8191)

System Realtime Messages

Active Sensing

Status

FEH

*This message is transmitted at intervals of approximately 250 msec.

*This message is not sent when Transmit Active Sensing parameter (SYSTEM Ctrl Tx) is OFF.

System Exclusive Messages

Universal Non-realtime System Exclusive Message and Data Set 1 (DT1) are the only System Exclusive messages transmitted by the V-Synth.

Universal Non-realtime System Exclusive Message

Identity Reply Message

Receiving Identity Request Message, the V-Synth send this message.

Status

Data byte

Status

F0H

 

7EH, dev, 06H, 02H, 41H, 53H, 01H,

F7H

 

 

00H, 00H, 00H, 01H, 00H, 00H

 

Byte

 

Explanation

 

F0H

 

Exclusive status

 

7EH

 

ID number (Universal Non-realtime Message)

dev

 

Device ID (dev: 10H - 1FH)

 

06H

 

Sub ID#1 (General Information)

 

02H

 

Sub ID#2 (Identity Reply)

 

41H

 

ID number (Roland)

 

53H

01H

Device family code

 

00H

00H

Device family number code

 

00H

01H 00H 00H Software revision level

 

F7H

 

EOX (End of Exclusive)

 

Data Transmission

Data Set 1

DT1 (12H)

 

 

Status

Data byte

 

Status

F0H

41H, dev, 00H, 53H, 12H, aaH, bbH,

F7H

 

ccH, ddH, eeH, ... ffH, sum

 

Byte

Explanation

 

 

F0H

Exclusive status

 

 

41H

ID number (Roland)

 

dev

Device ID (dev: 00H - 1FH, 7FH)

 

00H

Model ID #1 (V-Synth)

 

53H

Model ID #2 (V-Synth)

 

12H

Command ID (DT1)

 

aaH

Address MSB:

upper byte of the starting address of the data to be

 

 

sent

 

bbH

Address:

upper middle byte of the starting address of the data

 

 

to be sent

 

ccH

Address:

lower middle byte of the starting address of the data

 

 

to be sent

 

ddH

Address LSB:

lower byte of the starting address of the data to be

 

 

sent.

 

eeH

Data:

the actual data to be sent. Multiple bytes of data are

 

 

transmitted in order starting from the address.

:

:

 

 

ffH

Data

 

 

sum

Checksum

 

 

F7H

EOX (End Of Exclusive)

 

*The amount of data that can be transmitted at one time depends on the type of data, and data will be transmitted from the specified starting address and size. Refer to the address and size given in “Parameter Address Map” (p. 159).

*Data larger than 256 bytes will be divided into packets of 256 bytes or less, and each packet will be sent at an interval of about 20 ms.