Creating and Editing Samples (Sample Mode)

Limiter

Thres (Threshold Level)

Specifies the level (threshold level) at which the limiter will begin to function.

Value: -60–0 dB

Release (Release Time)

Specifies the time from when the input level drops below the threshold level until the limiter turns off.

Value: 0–127

Tone

Adjusts the tonal quality of the limiter.

Value: -50– +50

Level (Output Level)

Adjusts the output volume.

Value: 0– +24 dB

Ratio

Specifies the compression ratio.

Value: 1.5:1, 2:1, 4:1, 100:1

Noise Suppressor

Threshold (Threshold Level)

Specifies the level at which the noise suppressor will begin to operate. When the signal falls below the specified level, it will be muted.

Value: -60–0 dB

Release (Release Time)

Specifies the time from when the noise suppressor begins to operate until the volume reaches 0.

Value: 0–127

Metronome Settings

Metronome

Metro Type (Metronome Type)

Specifies when you want the metronome to sound.

Value

OFF: The metronome will not sound.

REC: The metronome will sound only during sampling.

ALWAYS: The metronome will sound whenever you sample (including while you are making settings in preparation for sampling).

Level (Metronome Level)

Specifies the volume of the metronome.

Value: 0–127

Count In

Specifies the number of measures for the count-in that will occur before sampling.

Value

OFF: A count will not be sounded.

1MEASURE: A one-measure count will be sounded.

2MEASURE: A two-measure count will be sounded.

If Trigger Mode is set to other than “MANUAL,” this parameter has no effect.

Tempo

Specifies the tempo of the metronome.

Value: 20.0–250.0

Beat

Specifies the time signature of the metronome.

Value

Numerator: 1–31

Denominator: 2, 4, 8, 16, 32

62

Page 62
Image 62
Roland V-Synth owner manual Metronome Settings