Roland V-Synth owner manual 155, Identity Request Message, Master Volume, Master Fine Tuning

Models: V-Synth

1 180
Download 180 pages 53.51 Kb
Page 155
Image 155

MONO (Controller number 126)

Status

2nd byte

3rd byte

BnH

7EH

mmH

n = MIDI channel number:

0H - FH (ch.1 - 16)

mm = mono number:

 

00H - 10H (0 - 16)

*The same processing will be carried out as when All Notes Off is received.

POLY (Controller number 127)

Status

2nd byte

3rd byte

BnH

7FH

00H

n = MIDI channel number: 0H - FH (ch.1 - 16)

*The same processing will be carried out as when All Notes Off is received.

System Realtime Message

Active Sensing

Status

FEH

*When Active Sensing is received, the unit will begin monitoring the intervals of all further messages. While monitoring, if the interval between messages exceeds 420 ms, the same processing will be carried out as when All Sounds Off, All Notes Off and Reset All Controllers are received, and message interval monitoring will be halted.

System Exclusive Message

Status

Data byte

Status

F0H

iiH, ddH, ......,eeH

F7H

F0H:

System Exclusive Message status

ii = ID number:

an ID number (manufacturer ID) to indicate the manufacturer whose

 

Exclusive message this is. Roland’s manufacturer ID is 41H.

 

ID numbers 7EH and 7FH are extensions of the MIDI standard;

 

Universal Non-realtime Messages (7EH) and Universal Realtime

 

Messages (7FH).

 

dd,...,ee = data:

00H - 7FH (0 - 127)

 

F7H:

EOX (End Of Exclusive)

Of the System Exclusive messages received by this device, the Universal Non-realtime messages and the Universal Realtime messages and the Data Request (RQ1) messages and the Data Set (DT1) messages will be set automatically.

Universal Non-realtime System Exclusive Messages

Identity Request Message

Status

Data byte

Status

F0H

7EH, dev, 06H, 01H

F7H

Byte

Explanation

 

F0H

Exclusive status

 

7EH

ID number (Universal Non-realtime Message)

dev

Device ID (dev: 10H - 1FH, 7FH)

06H

Sub ID#1 (General Information)

01H

Sub ID#2 (Identity Request)

F7H

EOX (End Of Exclusive)

*When this message is received, Identity Reply message (p. 158) will be transmitted.

MIDI Implementation

Universal Realtime System Exclusive Messages

Master Volume

Status

Data byte

Status

F0H

7FH, 7FH, 04H, 01H, llH, mmH

F7H

Byte

Explanation

 

F0H

Exclusive status

 

7FH

ID number (universal realtime message)

 

7FH

Device ID (Broadcast)

 

04H

Sub ID#1 (Device Control)

 

01H

Sub ID#2 (Master Volume)

 

llH

Master Volume lower byte

 

mmH

Master Volume upper byte

 

F7H

EOX (End Of Exclusive)

 

*The lower byte (llH) of Master Volume will be handled as 00H.

*The Master Level parameter (SYSTEM Com Master) will change.

Master Fine Tuning

Status

Data byte

Status

F0H

7FH, 7FH, 04H, 03H, llH, mmH

F7H

Byte

Explanation

 

F0H

Exclusive status

 

7FH

ID number (universal realtime message)

 

7FH

Device ID (Broadcast)

 

04H

Sub ID#1 (Device Control)

 

03H

Sub ID#2 (Master Fine Tuning)

 

llH

Master Fine Tuning LSB

 

mmH

Master Fine Tuning MSB

 

F7H

EOX (End Of Exclusive)

 

mm, ll: 00 00H - 40 00H - 7F 7FH (-100 - 0 - +99.9 [cents])

*The Master Tune parameter (SYSTEM Com Master) will change.

Master Coarse Tuning

Status

Data byte

Status

F0H

7FH, 7FH, 04H, 04H, llH, mmH

F7

Byte

Explanation

 

F0H

Exclusive status

 

7FH

ID number (universal realtime message)

 

7FH

Device ID (Broadcast)

 

04H

Sub ID#1 (Device Control)

 

04H

Sub ID#2 (Master Coarse Tuning)

 

llH

Master Coarse Tuning LSB

 

mmH

Master Coarse Tuning MSB

 

F7H

EOX (End Of Exclusive)

 

llH:

ignored (processed as 00H)

 

mmH:

28H - 40H - 58H (-24 - 0 - +24 [semitones])

 

*The Master Key Shift parameter (SYSTEM Com Master) will change.

Appendices

155

Page 155
Image 155
Roland V-Synth owner manual 155, Identity Request Message, Master Volume, Master Fine Tuning, Master Coarse Tuning