Roland V-Synth owner manual Sampling Procedure, Setup Comp Limiter NoiseSup, Touch Sample

Models: V-Synth

1 180
Download 180 pages 53.51 Kb
Page 56
Image 56

Creating and Editing Samples (Sample Mode)

Setup

Comp

Limiter

NoiseSup

MIDI

 

 

 

 

 

 

 

 

 

SamplingType

0

(Stereo)

0

(Stereo)

0

(Stereo)

0

(Stereo)

InputSource

0

(Analog)

0

(Analog)

0

(Analog)

0

(Analog)

TriggerMode

0

(Manual)

0

(Manual)

0

(Manual)

1

(MIDI)

TriggerLevel

-12 (dB)

-12 (dB)

-12 (dB)

-12 (dB)

PreTrigger

0

(0msec)

0

(0msec)

0

(0msec)

0

(0msec)

PreGain

0

(0dB)

0

(0dB)

0

(0dB)

0

(0dB)

PreFxType

1

(COMP)

2

(LIMIT)

3

(NS)

0

(off)

PreFxCS-Sus

64

0

 

0

 

0

 

PreFxCS-Atk

12

0

 

0

 

0

 

PreFxCS-Tone

0

 

0

 

0

 

0

 

PreFxCS-Lvl

0

 

0

 

0

 

0

 

PreFxLM-Thr

-48

-36

-48

-48

PreFxLM-Rel

0

 

80

0

 

0

 

PreFxLM-Rati

0

 

2

 

0

 

0

 

PreFxLM-Tone

0

 

0

 

0

 

0

 

PreFxLM-Lvl

0

 

0

 

0

 

0

 

PreFxNS-Thr

-60

-60

-30

-60

PreFxNS-Rel

0

 

0

 

22

0

 

CountIN

1

(1MES)

1

(1MES)

1

(1MES)

0

(0MES)

MetroType

1

(REC)

1

(REC)

1

(REC)

1

(REC)

Sampling Procedure

Here’s how to input a sound from the input jacks and sample it. For resampling, refer to the following section.

The V-Synth has the following input jacks.

INPUT L, R (GAIN: MIC/LINE)

DIGITAL AUDIO INTERFACE OPTICAL IN COAXIAL IN

Use the input jack that is appropriate for your situation.

• Monaural sampling from a mic →

INPUT L, R (GAIN: MIC)

• Sampling from an analog source →

INPUT L, R (GAIN: LINE)

• Sampling from a digital source →

OPTICAL IN or COAXIAL IN

Howling could be produced depending on the location of microphones relative to speakers. This can be remedied by:

1.Changing the orientation of the microphone(s).

2.Relocating microphone(s) at a greater distance from speakers.

3.Lowering volume levels.

When sampling, you must make sure that the following two items are set correctly. If these two settings are incorrect, the sample will not be recorded as you intend.

What type of sample are you recording? (stereo or mono)

In the SAMPLING General screen, set Sampling Type.

Which input are you sampling from? (select the input jack)

In the SAMPLING General screen, set Input Source.

If you have set the metronome (p. 62), the metronome sound will be output from the DIRECT OUT jack during sampling. However, the sound that is assigned to the DIRECT OUT jack (p.

50) will not be output.

1.Press [MODE].

The V-SYNTH MODE MENU window appears.

2.Touch <SAMPLE>.

The SAMPLE Top screen appears.

56

Page 56
Image 56
Roland V-Synth owner manual Sampling Procedure, Setup Comp Limiter NoiseSup, Touch Sample