Parameter

Value

Description

 

 

 

Mod Mode

CHORUS,

Selects whether to use chorus or

 

FLANGER

flanger.

 

 

 

Mod Rate

0.05–10.0 Hz,

Adjusts the speed of modulation

 

note

for the chorus or flanger.

 

 

 

Mod Depth

0–127

Adjusts the depth of modulation

 

 

for the chorus or flanger.

 

 

 

Mod Phase

0–180 deg

Sets how the chorus or flanger

 

 

sound is spread.

 

 

 

Mod Pre Delay

0–50.0 ms

Adjusts the delay time from the

 

 

direct sound until the chorus or

 

 

flanger sound is heard.

Mod Feedback

-98– +98 %

Adjusts the proportion of the ef-

 

 

fect sound that is fed back into

 

 

the effect. Negative (-) settings

 

 

will invert the phase.

 

 

 

Mod XoverLPF

500–15000 Hz,

Adjusts the cutoff frequency of

 

THRU

the low pass filter. (THRU: no

 

 

filter is used)

Mod XoverHPF

THRU, 50–800

Adjusts the cutoff frequency of

 

Hz

the high pass filter. (THRU: no

 

 

filter is used)

 

 

 

Mod Level

0–127

Volume of the chorus or flanger

 

 

sound.

 

 

 

Delay Time

0–1300 ms, note

Adjusts the delay time from the

 

 

direct sound until the delay

 

 

sound is heard.

 

 

 

Delay Feedback

-98– +98 %

Adjusts the proportion of the de-

 

 

lay sound that is fed back into

 

 

the effect. Negative (-) settings

 

 

will invert the phase.

 

 

 

Hi Damp Freq

500–15000 Hz,

Adjusts the frequency above

 

THRU

which sound fed back to the ef-

 

 

fect will be cut.

 

 

High Damp, by attenuating the

 

 

higher frequencies first, makes

 

 

the delay sound more natural.

 

 

 

Delay Level

0–127

Volume of the delay sound.

 

 

 

35: Bass Multi

Bass Multi provides Comp/Limiter, Overdrive or Distortion, 3-band equalizer, and Chorus or Flanger effects connected in series. This algorithm is a multi-effects for bass.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Comp/

 

 

Overdrive/

 

3-Band

 

 

Chorus/

 

 

 

 

 

 

Limiter

 

 

Distortion

 

 

EQ

 

 

Flanger

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Value

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Comp Sw

OFF, ON

 

 

Turns the comp/limiter on/off.

Comp Thresh-

-60–0 dB

 

 

Sets the volume level at which

old #1

 

 

 

 

 

the compression begins.

Comp Attack

0–127

 

 

Sets the time after the sound vol-

 

 

 

 

 

 

 

 

ume is crossed the compressor

 

 

 

 

 

 

 

 

threshold until compression be-

 

 

 

 

 

 

 

 

gins.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Comp Release

0–127

 

 

Specifies the time from when the

 

 

 

 

 

 

 

 

volume drops below the com-

 

 

 

 

 

 

 

 

pressor threshold until com-

 

 

 

 

 

 

 

 

pression is no longer applied.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Comp Ratio

1.5:1, 2:1, 4:1,

 

 

Sets the “source sound:output

 

 

 

100:1

 

 

sound” compression ratio.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Comp Gain

-60– +12 dB

 

 

Adjusts the output gain.

Parameter

Value

Description

 

 

 

Distortion Sw

OFF, ON

Selects whether to use overdrive

 

 

or distortion.

 

 

 

Distortion

OD, DS

Selects whether to use overdrive

Mode

 

(OD) or distortion (DS).

 

 

 

Drive

0–127

Degree of distortion

 

 

 

Amp Sim Sw

OFF, ON

Turns the amp simulator on/off.

Amp Type

SMALL,

Type of guitar amp

 

BUILT-IN, 2-

SMALL: small amp

 

STACK, 3-

BUILT-IN: single-unit type amp

 

STACK

2-STACK: large double stack

 

 

amp

 

 

3-STACK: large triple stack amp

 

 

 

Distortion Level

0–127

Volume of the overdrive or dis-

 

 

tortion sound.

 

 

 

EQ Low Freq

50–4000 Hz

Frequency of the low range

EQ Low Gain

-15– +15 dB

Gain of the low range

EQ Mid Freq

50–20000 Hz

Frequency of the middle range

 

 

 

EQ Mid Q

0.5, 0.7, 1.0, 2.0,

Gain of the middle range

 

4.0, 8.0

Set a higher value for Q to nar-

 

 

row the range to be affected.

 

 

 

EQ Mid Gain

-15– +15 dB

Gain of the middle range

 

 

 

EQ Hi Freq

2000–20000 Hz

Frequency of the high range

EQ Hi Gain

-15– +15 dB

Gain of the high range

Mod Mode

CHORUS,

Selects whether to use chorus or

 

FLANGER

flanger.

 

 

 

Mod Rate

0.05–10.0 Hz,

Adjusts the speed of modulation

 

note

for the chorus or flanger.

 

 

 

Mod Depth

0–127

Adjusts the depth of modulation

 

 

for the chorus or flanger.

 

 

 

Mod Phase

0–180 deg

Sets how the chorus or flanger

 

 

sound is spread.

 

 

 

Mod Pre Delay

0–50.0 ms

Adjusts the delay time from the

 

 

direct sound until the chorus or

 

 

flanger sound is heard.

Mod Feedback

-98– +98 %

Adjusts the proportion of the ef-

 

 

fect sound that is fed back into

 

 

the effect. Negative (-) settings

 

 

will invert the phase.

 

 

 

Mod XoverLPF

500–15000 Hz,

Adjusts the cutoff frequency of

 

THRU

the low pass filter. (THRU: no

 

 

filter is used)

Mod XoverHPF

THRU, 50–800

Adjusts the cutoff frequency of

 

Hz

the high pass filter. (THRU: no

 

 

filter is used)

 

 

 

Mod Level

0–127

Volume of the chorus or flanger

 

 

sound.

 

 

 

134