Sanyo DSR-3009P instruction manual Pre-alarm recording setting, Recording Setting

Models: DSR-3009P

1 95
Download 95 pages 9.88 Kb
Page 63
Image 63
 Pre-alarm recording setting

RECORDING SETTING

Manual background Pre-alarm recording setting

 

<ALARM REC MODE SET>

 

PICTURE QUALITY

:

SUPER FINE

 

AUDIO

RECORDING

:

ON

 

ALARM

RECORDING

:

ENABLED

 

ALARM

INTERLEAVE

:

SW

 

PROGRAM GROUP

:

OFF

 

REC

RATE: @ 8.33FPS,

DURATION:

5SEC

PRE-ALARM RECORDING

:

ON

 

REC

RATE: @ **** FPS,

DURATION:

***

=>

(01010 ALARMS CAN BE RECORDED )

 

ALARM

TRIGGER

:

ALARM

 

1 Use the jog dial to move the cursor to ALARM RECORDING, and then turn the shuttle dial clockwise.

OFF” flashes.

2 Use the jog dial to change the “OFF” setting to some other mode (example: ENABLED), and then turn the shuttle dial clockwise.

The PRE-ALARM RECORDING setting changes from “ ” to “OFF”.

The cursor moves to REC RATE.

3 Use the jog dial to move the cursor to PRE-ALARM RECORDING, and then turn the shuttle dial clockwise.

OFF” flashes.

4 Use the jog dial to change from “OFF” to “ON” , and then turn the shuttle dial clockwise.

The cursor moves to REC RATE.

ALARM INTERLEAVE

:

ONLY

PROGRAM GROUP

 

:

OFF

REC RATE: @

8.33FPS,

DURATION: 40SEC

PRE-ALARM RECORDING

:

ON

 

REC RATE: @

****

FPS,

DURATION: ***

 

=> (01010 ALARMS

CAN BE RECORDED )

ALARM TRIGGER

 

:

ALARM

5 Turn the shuttle dial clockwise, use the jog dial to set the recording speed, and then turn the shuttle dial clockwise.

The cursor moves to the “2SEC” setting for DURATION and flashes.

6 Use the jog dial to set the recording time duration (example: “5SEC” ), and then turn the shuttle dial clockwise.

The cursor moves to ALARM TRIGGER.

ALARM

INTERLEAVE

:

ONLY

 

PROGRAM GROUP

 

:

OFF

 

REC

RATE: @

8.33FPS,

DURATION:

5SEC

PRE-ALARM RECORDING

:

ON

 

REC

RATE: @

12.5FPS,

DURATION:

5

=>

(01010 ALARMS CAN BE RECORDED )

 

ALARM

TRIGGER

 

:

ALARM

 

 

7 Use the jog dial to move the cursor to PROGRAM GROUP, turn the shuttle dial clockwise, use the jog dial to set the program number (example: “P-1"), and then turn the shuttle dial clockwise.

The cursor moves to REC RATE.

Display examples:

OFF: Pre-alarm images from all cameras are recorded at the same recording speed.

P-1:When program no. 1 is recorded

P-2:When program no. 2 is recorded

P-3:When program no. 3 is recorded

P-4:When program no. 4 is recorded

Note: When pre-alarm recording has been set, the pre-alarm recording speed and the recording speed for normal recording will be fixed at 15 FPS. A warning screen appears to verify confirm this, so select “YES”.

8 Press the EXIT/OSD button.

The display returns to the normal screen.

PRE” appears in the operating display section. When an alarm is triggered, the display switches to “ALARM”.

EXIT/OSD

 

01

 

 

 

PRE 0000

SF 01-01-02 06:46:15

 

 

 

 

 

 

 

 

 

 

 

 

Note:

Pre-alarm recording continues for the length of time specified by the DURATION setting before an alarm signal is input. When playing back images that have been recorded during pre-alarm recording, use the alarm search (SEARCH button) operations. Images will be played back from the point that the alarm occurred, so use the shuttle operations to carry out rewind playback.

If carrying out normal alarm recording and pre-alarm recording at the same time, no audio signals will be recorded with the pre-alarm recording images.

62

English

Page 63
Image 63
Sanyo DSR-3009P instruction manual Pre-alarm recording setting, Recording Setting