RECORDING SETTING

5 Turn the shuttle dial clockwise, use the jog dial to set audio recording (example: “ON” ), and then turn the shuttle dial clockwise.

The cursor moves to ALARM RECORDING.

 

<ALARM REC MODE SET>

PICTURE QUALITY

:

SUPER FINE

AUDIO

RECORDING

:

ON

ALARM

RECORDING

:

OFF

 

ALARM

INTERLEAVE

:

ONLY

 

PROGRAM GROUP

:

OFF

REC

RATE: @

25FPS,

DURATION: 5SEC

PRE-ALARM RECORDING :

¤¤¤

 

Note:

Audio recording can be set when the REC RATE setting is 5 FPS or 10 FPS or more.

When set to “ON”, the letter “A” (audio recording indicator) appears in front of the REC RATE recording speed, and the maximum number of recordings appears underneath it (at the bottom of the screen).

=> (30200 ALARMS CAN BE RECORDED)

6 Turn the shuttle dial clockwise, use the jog dial to set alarm recording mode (example: “ENABLED” ), and then turn the shuttle dial.

The cursor moves to ALARM INTERLEAVE.

Display example: Alarm recording settings

OFF: Alarm recording is not carried out.

ENABLED: Alarm recording is always carried out regardless of the timer recording settings.

AL-REC ON TIMER: Alarm recording is only carried out when timer recording is in progress.

AL-REC OFF TIMER: Alarm recording is only carried out when timer recording is not in progress

OLY AL-RC ON TMR: Alarm recording is carried out only during the times set by the timer. This cannot be used for normal recording.

Note: If alarm recording is set to a setting such as ENABLED,

PRE-ALARM RECORDING setting will be enabled (“ ” will change to “OFF”).

7 Turn the shuttle dial clockwise, use the jog dial to select the ALARM INTERLEAVE setting (example: “SW” ), and then turn the shuttle dial clockwise.

The cursor moves to PROGRAM GROUP.

 

<ALARM REC MODE SET>

PICTURE QUALITY

:

SUPER FINE

AUDIO

RECORDING

:

ON

ALARM

RECORDING

:

ENABLED

ALARM

INTERLEAVE

:

SW

PROGRAM GROUP

:

OFF

DURATION: 5SEC

REC

RATE: @

25FPS,

 

PRE-ALARM RECORDING :

¤¤¤

 

Display examples:

ONLY: (See page 61.)

SW: (See page 61.)

8 Turn the shuttle dial clockwise, use the jog dial to set the recording speed (example: “8.33” ), and then turn the shuttle dial clockwise.

DURATION of “5SEC” flashes.

Note: When the recording speed is selected, the maximum number of recordings appears underneath it (at the bottom of the screen).

=> (20480 ALARMS CAN BE RECORDED)

9 Use the jog dial to set the recording time duration (example: “5” ), and then turn the shuttle dial.

The cursor moves to PRE-ALARM RECORDING.

Display examples:

5S – 15M: The same duration has been set for all cameras.

CC: Operates while an alarm is being received (minimum

1second).

INDIV: Individual durations have been set for each camera.

 

<ALARM REC MODE SET>

 

PICTURE QUALITY

:

SUPER FINE

 

AUDIO

RECORDING

:

ON

 

ALARM

RECORDING

:

ENABLED

 

ALARM

INTERLEAVE

:

SW

 

PROGRAM GROUP

:

P-1

 

REC

RATE: @ 8.33FPS,

DURATION:

5SEC

PRE-ALARM RECORDING

:

¤¤¤

DURATION:

***

REC

RATE: @ **** FPS,

 

=>

(16000 ALARMS CAN BE RECORDED )

 

ALARM

TRIGGER

:

ALARM

 

10 Press the EXIT/OSD button.

The display returns to the normal screen.

Alarm settings appear in the operating display section. When an alarm is triggered, the number of alarms is displayed.

EXIT/OSD

 

01

 

 

 

ALARM 0000

SF 01-01-02 05:53:44

 

 

 

 

 

 

 

 

 

 

 

 

Note: If another alarm occurs at another channel while alarm recording is in progress, the alarm count increases and the alarms are treated as two alarms. If another alarm occurs at the same channel, the alarms are treated as a single alarm (the alarm count is not increased).