SCREEN SETTING

9 Press the EXIT/OSD button.

The display returns to the normal screen.

EXIT/OSD

Example 3: To set a 5-second interval for the automatic switching of main monitor images and to prevent automatic switching from occurring when it is not required, such as when using the timer function.

 

<MAIN MONITOR SET>

 

 

 

T-1

 

IN

IN

IN

IN

01:ON

02:ON

03:ON

04:ON

05:ON

06:ON

07:ON

08:ON

09:ON

10:ON

11:ON

12:ON

13:ON

14:ON

15:ON

16:ON

1 Set the timer setting for both TIMER A and TIMER B in the TIME PERIOD SET menu. (See page 46.)

Set both TIMER A and TIMER B.

<TIME PERIOD SET>

 

 

TIME PERIOD

T1

T2

T3

T4

TIME PERIOD A

00:00

00:00

00:00

00:00

TIME PERIOD B

00:00

00:00

00:00

00:00

SELECT TIME PERIOD

 

 

 

SEQUENCE

TIME PERIOD

A

 

MASK

TIME PERIOD

A

 

MOTION SENSOR

TIME PERIOD

A

 

2 Use the jog dial to move the cursor to SEQUENCE, and then turn the shuttle dial clockwise.

1S” flashes.

<SCREEN SET>

 

 

 

 

1.MULTI SCREEN

:

NORMAL

MULTI SCREEN SET

 

->

2.SEQUENCE

:

 

1S

 

SEQUENCE SET

 

 

 

->

3.MASK

:

OFF

MASK SET

 

->

3 Use the jog dial to change the SEQUENCE setting to “INDIV.” , and then turn the shuttle dial clockwise.

The cursor moves to SEQUENCE SET.

4 Turn the shuttle dial clockwise.

The SEQUENCE SET sub-menu appears.

<SEQUENCE SET>

 

MAIN MONITOR

:

1S

MAIN MONITOR SET

 

->

MON.2

:

1S

MON.2 SET

 

->

QUAD

:

1S

INDIVIDUAL INTERVAL

SET

->

5 Turn the jog dial to select MAIN MONITOR, and then turn the shuttle dial clockwise.

1S” flashes.

6 Use the jog dial to set “5S” , and then turn the shuttle dial clockwise.

The cursor moves to MAIN MONITOR SET.

Display examples:

1 – 30S: Sets the automatic switching time for the main monitor.

INDIV. : Select when setting individual switching times for each camera for the main monitor.

7 Turn the shuttle dial clockwise.

The MAIN MONITOR SET sub-menu will be displayed. This sub-menu screen is used to select whether the images from cameras 1 to 16 are displayed or not displayed for the time set by the timer setting (T-1).

8 Turn the shuttle dial clockwise, use the jog dial to select “T-1” , and then turn the shuttle dial clockwise.

The cursor moves to 01.

9 Use the jog dial to move the cursor to CAMERA 1 (01), and then turn the shuttle dial clockwise.

ON” flashes.

10Use the jog dial to set “OFF” , and then turn the shuttle dial clockwise.

Repeat the above procedure to set cameras 2 (02) through to 8 (08) to “OFF”.

<MAIN MONITOR SET>

 

 

T-1

 

 

IN

IN

IN

IN

01:OFF

02:OFF

03:OFF

04:OFF

05:OFF

06:OFF

07:OFF

08:OFF

09:ON

10:ON

11:ON

12:ON

13:ON

14:ON

15:ON

16:ON

11Use the jog dial to move the cursor to T-1, and then turn the shuttle dial clockwise.

84

English

Page 85
Image 85
Sanyo DSR-3009P instruction manual Set both Timer a and Timer B, Cursor moves to Main Monitor SET