Technical data and characteristics 14.2 Data sheets and diagrams
Data sheet 1FW6090-xxB15-xxxx
Table 14- 4
Technical data | Symbol | Unit | ||
1FW6090 |
|
|
|
|
Boundary conditions |
|
|
|
|
DC link voltages | UZK | V | 600 | 600 |
Water cooling inlet temperature | TVORL | °C | 35 | 35 |
Rated temperature of winding | TN | °C | 130 | 130 |
Rated data |
|
|
|
|
Rated torque | MN | Nm | 338 | 319 |
Rated current | IN | A | 15 | 23 |
Maximum speed at rated torque | nMAX,MN | rpm | 150 | 310 |
Rated power dissipation | PV,N | kW | 4.87 | 4.96 |
Limit data |
|
|
|
|
Maximum torque | MMAX | Nm | 537 | 537 |
Maximum current | IMAX | A | 26 | 43 |
Electric power of motor at MMAX | PEL,MAX | kW | 17.1 | 24.1 |
Maximum speed at maximum torque | nMAX,MMAX | rpm | 78 | 200 |
nMAX,0 | rpm | 290 | 470 | |
Torque at n = 1 [rpm] | M0 | Nm | 357 | 357 |
Current at M0 and n = 1 [rpm] | I0 | A | 16 | 26 |
Thermal static torque | M0* | Nm | 252 | 252 |
Thermal stall current | I0* | A | 11 | 18 |
Physical constants |
|
|
|
|
Torque constant at 20 °C | kT,20 | Nm/A | 22.5 | 13.7 |
Voltage constant | kE | V/(1000/min) | 1359 | 831.3 |
Motor constant at 20 °C | kM,20 | Nm/(W)0.5 | 5.3 | 5.25 |
Thermal time constant | tTH | s | 60 | 60 |
No. of pole pairs | p | - | 22 | 22 |
Cogging torque | MCOG | Nm | 3.6 | 3.6 |
Stator mass | mS | kg | 19.5 | 19.5 |
Rotor mass | mL | kg | 7.7 | 7.7 |
Rotor moment of inertia | JL | 4.65 | 4.65 | |
Phase resistance of winding at 20 °C | RSTR, 20 | Ω | 4.3 | 1.64 |
Phase inductance of winding | LSTR | mH | 17.7 | 6.6 |
Data, main motor cooler |
|
|
|
|
Maximum dissipated thermal power | QH,MAX | kW | 4.05 | 4.13 |
Recommended minimum volume flow rate | H,MIN | l/min | 7 | 7 |
Temperature increase of the coolant | ΔTH | K | 8.3 | 8.5 |
Pressure drop | ΔpH | bar | 0.6 | 0.6 |
188 |
|
|
| 1FW6 |
| Configuration Manual, 05/2009, |