11.4Test and replacement intervals of the cooling medium

Regularly check that the rotary axes can move without hindrance.

Keep the air gap free of chippings and particles.

Regularly check the condition of the motor components.

Check the current consumption in the test cycle defined beforehand.

Ensure that the motor compartment remains free of contamination (e.g. chippings, oil, etc.). Depending on the local level of contamination, clean the machine to ensure that it functions properly and that heat loss is properly dissipated.

Check the cables to ensure that they are not damaged and are free of wear and tear. Do not use electrical devices with damaged cables.

Make sure that the cable glands are secure.

Intervals between maintenance

Since operating conditions differ greatly, it is not possible to specify intervals between maintenance work.

Indications that maintenance work is required

Dirt in the motor cabinet

Distinctive changes in the behavior of the machine

Unusual sounds emitted by the machine

Problems with positioning accuracy

Higher current consumption

11.4Test and replacement intervals of the cooling medium

Test and replacement intervals of the cooling medium

The test and replacement intervals for the cooling medium should be agreed with the manufacturers of the anti-corrosion agent and the cooling system.