Siemens S120 configurationmanual Data sheet 1FW6190-xxB15-xxxx, Rated data

Models: S120

1 301
Download 301 pages 40.03 Kb
Page 238
Image 238

Technical data and characteristics 14.2 Data sheets and diagrams

Data sheet 1FW6190-xxB15-xxxx

Table 14- 27 1FW6190-xxB15-2Jxx, 1FW6190-xxB15-5Gxx, 1FW6190-xxB15-8Fxx

Technical data

Symbol

Unit

-xxB15-2Jxx

-xxB15-5Gxx

-xxB15-8Fxx

1FW6190

 

 

 

 

 

Boundary conditions

 

 

 

 

 

DC link voltages

UZK

V

600

600

600

Water cooling inlet temperature

TVORL

°C

35

35

35

Rated temperature of winding

TN

°C

130

130

130

Rated data

 

 

 

 

 

Rated torque

MN

Nm

1970

1890

1820

Rated current

IN

A

26

50

69

Maximum speed at rated torque

nMAX,MN

rpm

40

100

160

Rated power dissipation

PV,N

kW

8.14

8.14

8.39

Limit data

 

 

 

 

 

Maximum torque

MMAX

Nm

2970

2970

2970

Maximum current

IMAX

A

47

95

130

Electric power of motor at MMAX

PEL,MAX

kW

30.1

44.1

55.6

Maximum speed at maximum torque

nMAX,MMAX

rpm

17

62

97

No-load speed

nMAX,0

rpm

88

180

250

Torque at n = 1 [rpm]

M0

Nm

2020

2020

2020

Current at M0 and n = 1 [rpm]

I0

A

27

54

78

Thermal static torque

M0*

Nm

1430

1430

1430

Thermal stall current

I0*

A

18

37

53

Physical constants

 

 

 

 

 

Torque constant at 20 °C

kT,20

Nm/A

77.3

38.7

27.1

Voltage constant

kE

V/(1000/min)

4676

2338

1637

Motor constant at 20 °C

kM,20

Nm/(W)0.5

23.4

23.4

23.1

Thermal time constant

tTH

s

180

180

180

No. of pole pairs

p

-

42

42

42

Cogging torque

MCOG

Nm

10

10

10

Stator mass

mS

kg

77.8

77.8

77.8

Rotor mass

mL

kg

30

30

30

Rotor moment of inertia

JL

10-2kgm2

99.8

99.8

99.8

Phase resistance of winding at 20 °C

RSTR, 20

Ω

2.6

0.651

0.329

Phase inductance of winding

LSTR

mH

28

7

3.4

Data for main motor cooler *)

 

 

 

 

 

Maximum dissipated thermal power

QH,MAX

kW

6.11

6.11

6.3

Recommended minimum volume flow

H,MIN

l/min

8.8

8.8

8.8

Temperature increase of the coolant

ΔTH

K

9.9

9.9

10.2

Pressure drop

ΔpH

bar

1.4

1.4

1.4

1FW6 Built-in torque motors

 

 

 

 

239

Configuration Manual, 05/2009, 6SN1197-0AE00-0BP3

 

 

 

 

Page 238
Image 238
Siemens S120 configurationmanual Data sheet 1FW6190-xxB15-xxxx, Rated data