Motor components of the built-in motor and options 3.3 Cooling

Coolant intake temperature

The intake temperatures must be selected in such a way that no condensation forms on the surface of the motor. Condensation can lead to corrosion in the machine.

Tkühl ≥ TUmgeb - 2 K

The motors are designed in accordance with DIN EN 60034–1 for operation at coolant temperatures of up to 35°C (rated value of the coolant intake temperature). If the intake temperature is different, the continuous motor current changes as shown below:

,QIOXHQFHRIFRRODQWLQOHWWHPSHUDWXUH

,1RILQFXUUHQWPRWRU&RQWLQXRXV

,QOHWWHPSHUDWXUHRIWKHPDLQFRROHULQr&

Figure 3-3 Principal dependency of the continuous motor current on the intake temperature of water cooling in the main cooler when the rotor losses are disregarded

Heat-exchanger unit

A heat-exchanger unit must be used to ensure a coolant inlet temperature of 35°C. More than one motor can be operated on a single heat-exchanger unit. The heat-exchanger units are not included in the scope of supply.

The cooling power is calculated from the sum of the power losses of the connected motors. The pump power must be adjusted in accordance with the specified flow and pressure loss of the cooling circuit.

For a list of companies and addresses from whom you can obtain heat-exchanger units, see the appendix.

Dimensioning the heat-exchanger unit

The power loss generated in the motor during continuous operation causes a heat flow, most of which is dissipated via the coolant in the cooling system. A smaller proportion of it is dissipated via the surrounding machine construction. The cooling power of the heat- exchanger unit in the cooling system must be designed in such a way that it can dissipate at least 85 - 90% of the generated power loss. If several motors are operated simultaneously on one cooling system, this value applies to the combined total power loss.

1FW6 Built-in torque motors

Configuration Manual, 05/2009, 6SN1197-0AE00-0BP3

51