Siemens S120 configurationmanual With connectors not in the case of motors with single cores

Models: S120

1 301
Download 301 pages 40.03 Kb
Page 25
Image 25

Description of the motor 2.2 Technical features

Technical feature

Version

Cooling method

Water cooling:

 

Jacket cooling, size 1FW609, 1FW613, 1FW615

 

Integrated cooling, size 1FW616, 1FW619, 1FW623, 1FW629

Pressure in the cooling circuit

Max. 10 bar (static)

Cooler connection

Motors with a cooling jacket:

 

Must be connected by customer

 

Motors with integrated cooling:

 

Connection with/without cooling connection adapter (see

 

"Installing the motor")

Temperature sensor

2 x PTC thermistor triplet with response threshold +130 /150 °C

 

(to DIN 44081/44082) and 1 x KTY84 thermistor (to EN 60034-

 

11) in the stator.

Insulation of stator winding

Temperature class 155 (F)

according to EN 60034-1

 

 

 

Magnet material

Rare earth material

Connection, electrical

Cable outlet:

 

Axial

 

radial outward

 

tangential (not in the case of motors with single cores)

 

Connection type:

 

Permanently connected power and signal cables with open core

 

ends

 

Length: 2 m

 

Permanently connected power cables with single cores and

 

signal cables with open core ends

 

Length: 1 m

 

Permanently connected power and signal cables pre-assembled

 

with connectors (not in the case of motors with single cores)

 

Length: 0.5 m

Motor supply cables

For the specifications of the motor supply cables, see

 

"Interfaces".

Torque ripple

≤ 1.5% M0

Ambient conditions for long-term storage, transport, and use in fixed locations

Based on DIN EN 60721-3-1 (for long-term storage), DIN EN 60721-3-2 (for transport), and DIN EN 60721-3-3 (for use in fixed, weather-protected locations)

Table 2- 2

Climatic ambient conditions

 

 

Lower air temperature limit:

- 5 °C

Upper air temperature limit:

+ 40 °C (deviates from 3K5)

Lower relative humidity limit:

5 %

Upper relative humidity limit:

85 %

Rate of temperature fluctuations:

< 0.5 K/min

Condensation:

Not permissible

Formation of ice:

Not permissible