Siemens S120 Motors with integrated cooling, 1FW6 motor components with a cooling jacket

Models: S120

1 301
Download 301 pages 40.03 Kb
Page 41
Image 41

Motor components of the built-in motor and options 3.1 Overview of the motor construction

5RWRUZLWK6WDWRUZLWK

SHUPDQHQWPDJQHWVFRROLQJMDFNHW

7UDQVSRUWDWLRQORFNV

(OHFWULFDOFRQQHFWLRQV

Figure 3-1 1FW6 motor components with a cooling jacket

Scope of delivery of the built-in torque motor with a cooling jacket

The rotor is secured in the stator by means of transportation locks and a spacer film

Stator with a cooling jacket; one cable for the power connection and one cable for the signal connection with connector or open core ends

Transportation locks with spacers and screws

O-rings (x 2) 2)

Motor rating plate (attached); additional motor rating plate (not attached)

Safety information

Motors with integrated cooling

These motors are equipped with a ready-to-connect, integrated dual-circuit cooling system, which provides considerable thermal insulation vis-à-vis the mechanical axes construction.

The dual-circuit cooling system comprises a main and precision cooler (thermo-sandwich® principle).

An internal cooling circuit (main cooler) dissipates most of the winding losses Pv of the stator. A thermal insulation layer between the stator and the mounting flanges of the stator prevents heat from flowing from the motor winding to the machine construction.

Any heat that does flow through the insulation layer is captured, for the most part, by a second heat sink (precision cooler) on the flange surfaces and dissipated. This ensures that the temperature on the mounting surfaces of the stator remains suitably low under all permissible operating conditions.

42

1FW6 Built-in torque motors

Configuration Manual, 05/2009, 6SN1197-0AE00-0BP3

Page 41
Image 41
Siemens S120 configurationmanual Motors with integrated cooling, 1FW6 motor components with a cooling jacket