Motor components of the built-in motor and options 3.2 Thermal motor protection

Table 3- 2 Technical data for the PTC thermistor triplet (PTC triplet)

Name

Description

Type

PTC triplet (acc. to DIN 44082- M180)

Response temperature

130 °C ± 5 K

(rated response temperature ϑNAT)

150 °C ± 5 K

PTC resistance (20 °C) at the triplet

≤ 3 · 250 Ω (750 Ω), refer to the characteristic

from - 20 °C up to ϑNAT - 20K

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum triplet resistance when hot

 

 

 

at T = ϑNAT – 5 K

≤ 3 · 550 Ω (1650 Ω), refer to the characteristic

at T = ϑNAT + 5 K

≥ 3 · 1330 Ω (3990 Ω), refer to the characteristic

at T = ϑNAT + 15 K

≥ 3 · 4000 Ω (12000 Ω), refer to the characteristic

Connection

Connect signal cable with connector to SME12x

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

module.

Application

It is mandatory that a PTC triplet is connected in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

order to protect the motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

against overtemperature. At the very least, the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temp-S must be connected with the rated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

response temperature of 130°C.

Typical characteristic R(ϑ) of a PTC temperature

 

 

 

sensor

 

 

 

Temp-S comprises 3 PTC temperature sensors

 

 

 

connected in series!

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

37&

Note

As a result of the additional PTC to monitor the power connection, the values for the PTC resistance and the minimum resistance change when warm. Factor "4" must be used instead of factor "3".

1FW6 Built-in torque motors

45

Configuration Manual, 05/2009, 6SN1197-0AE00-0BP3

Page 44
Image 44
Siemens S120 configurationmanual Name Description