Technical data and characteristics 14.2 Data sheets and diagrams

Technical data

Symbol

Unit

-xxB10-8Fxx

-xxB10-2Pxx

1FW6160

 

 

 

 

Phase resistance of winding at 20 °C

RSTR, 20

Ω

0.182

0.0906

Phase inductance of winding

LSTR

mH

1.8

0.9

Data for main motor cooler *)

 

 

 

 

Maximum dissipated thermal power

QH,MAX

kW

3.68

3.59

Recommended minimum volume flow

H,MIN

l/min

6.4

6.4

Temperature increase of the coolant

ΔTH

K

8.3

8.1

Pressure drop

ΔpH

bar

0.8

0.8

Data for precision motor cooler *)

 

 

 

 

Maximum dissipated thermal power

QP,MAX

kW

0.397

0.387

Recommended minimum volume flow

P,MIN

l/min

2.5

2.5

Temperature increase of the coolant

ΔTP

K

2.3

2.2

Pressure drop

ΔpH

bar

0.8

0.8

*) Parallel connection of main and precision motor cooler