Technical data and characteristics 14.2 Data sheets and diagrams
Data sheet 1FW6090-xxB07-xxxx
Table 14- 2
Technical data | Symbol | Unit | ||
1FW6090 |
|
|
|
|
Boundary conditions |
|
|
|
|
DC link voltages | UZK | V | 600 | 600 |
Water cooling inlet temperature | TVORL | °C | 35 | 35 |
Rated temperature of winding | TN | °C | 130 | 130 |
Rated data |
|
|
|
|
Rated torque | MN | Nm | 154 | 142 |
Rated current | IN | A | 9.5 | 13 |
Maximum speed at rated torque | nMAX,MN | rpm | 220 | 430 |
Rated power dissipation | PV,N | kW | 2.69 | 2.67 |
Limit data |
|
|
|
|
Maximum torque | MMAX | Nm | 251 | 251 |
Maximum current | IMAX | A | 16 | 26 |
Electric power of motor at MMAX | PEL,MAX | kW | 10.3 | 14.1 |
Maximum speed at maximum torque | nMAX,MMAX | rpm | 120 | 270 |
nMAX,0 | rpm | 390 | 620 | |
Torque at n = 1 [rpm] | M0 | Nm | 166 | 166 |
Current at M0 and n = 1 [rpm] | I0 | A | 10 | 16 |
Thermal static torque | M0* | Nm | 118 | 118 |
Thermal stall current | I0* | A | 7.1 | 11 |
Physical constants |
|
|
|
|
Torque constant at 20 °C | kT,20 | Nm/A | 16.6 | 10.5 |
Voltage constant | kE | V/(1000/min) | 1007 | 634.3 |
Motor constant at 20 °C | kM,20 | Nm/(W)0.5 | 3.33 | 3.34 |
Thermal time constant | tTH | s | 60 | 60 |
No. of pole pairs | p | - | 22 | 22 |
Cogging torque | MCOG | Nm | 1.7 | 1.7 |
Stator mass | mS | kg | 8.6 | 8.6 |
Rotor mass | mL | kg | 3.6 | 3.6 |
Rotor moment of inertia | JL | 2.2 | 2.2 | |
Phase resistance of winding at 20 °C | RSTR, 20 | Ω | 5.98 | 2.36 |
Phase inductance of winding | LSTR | mH | 21.2 | 8.4 |
Data, main motor cooler |
|
|
|
|
Maximum dissipated thermal power | QH,MAX | kW | 2.24 | 2.22 |
Recommended minimum volume flow rate | H,MIN | l/min | 4.1 | 4.1 |
Temperature increase of the coolant | ΔTH | K | 7.8 | 7.8 |
Pressure drop | ΔpH | bar | 0.2 | 0.2 |
184 |
|
|
| 1FW6 |
| Configuration Manual, 05/2009, |