Technical data and characteristics 14.2 Data sheets and diagrams

Technical data

Symbol

Unit

-xxB07-5Gxx

-xxB07-0Lxx

-xxB07-2Pxx

1FW6290

 

 

 

 

 

Temperature increase of the coolant

ΔTH

K

9.7

9.7

9.7

Pressure drop

ΔpH

bar

0.4

0.4

0.4

Data for precision motor cooler *)

 

 

 

 

 

Maximum dissipated thermal power

QP,MAX

kW

0.42

0.42

0.421

Recommended minimum volume flow

P,MIN

l/min

2.2

2.2

2.2

Temperature increase of the coolant

ΔTP

K

2.7

2.7

2.7

Pressure drop

ΔpH

bar

0.4

0.4

0.4

*) Parallel connection of main and precision motor cooler

1FW6 Built-in torque motors