Technical data and characteristics 14.2 Data sheets and diagrams
Technical data | Symbol | Unit | |||
1FW6290 |
|
|
|
|
|
Temperature increase of the coolant | ΔTH | K | 9.7 | 9.7 | 9.7 |
Pressure drop | ΔpH | bar | 0.4 | 0.4 | 0.4 |
Data for precision motor cooler *) |
|
|
|
|
|
Maximum dissipated thermal power | QP,MAX | kW | 0.42 | 0.42 | 0.421 |
Recommended minimum volume flow | P,MIN | l/min | 2.2 | 2.2 | 2.2 |
Temperature increase of the coolant | ΔTP | K | 2.7 | 2.7 | 2.7 |
Pressure drop | ΔpH | bar | 0.4 | 0.4 | 0.4 |
*) Parallel connection of main and precision motor cooler
1FW6 | 269 |
Configuration Manual, 05/2009, |