Siemens S120 configurationmanual 253

Models: S120

1 301
Download 301 pages 40.03 Kb
Page 252
Image 252

 

 

 

 

Technical data and characteristics

 

 

 

 

14.2 Data sheets and diagrams

 

 

 

 

 

 

 

Technical data

Symbol

Unit

-xxB07-8Fxx

 

1FW6230

 

 

 

 

 

Rotor moment of inertia

JL

10-2kgm2

84.3

 

 

Phase resistance of winding at 20 °C

RSTR, 20

Ω

0.197

 

 

Phase inductance of winding

LSTR

mH

1.9

 

 

Data for main motor cooler *)

 

 

 

 

 

Maximum dissipated thermal power

QH,MAX

kW

3.4

 

 

Recommended minimum volume flow

H,MIN

l/min

6.1

 

 

Temperature increase of the coolant

ΔTH

K

8

 

 

Pressure drop

ΔpH

bar

0.8

 

 

Data for precision motor cooler *)

 

 

 

 

 

Maximum dissipated thermal power

QP,MAX

kW

0.367

 

 

Recommended minimum volume flow

P,MIN

l/min

2.1

 

 

Temperature increase of the coolant

ΔTP

K

2.5

 

 

Pressure drop

ΔpH

bar

0.8

 

*) Parallel connection of main and precision motor cooler

1FW6 Built-in torque motors

253

Configuration Manual, 05/2009, 6SN1197-0AE00-0BP3