Technical data and characteristics 14.2 Data sheets and diagrams

Data sheet 1FW6130-xxB07-xxxx

Table 14- 6 1FW6130-xxB07-0Kxx, 1FW6130-xxB07-1Jxx

Technical data

Symbol

Unit

-xxB07-0Kxx

-xxB07-1Jxx

1FW6130

 

 

 

 

Boundary conditions

 

 

 

 

DC link voltages

UZK

V

600

600

Water cooling inlet temperature

TVORL

°C

35

35

Rated temperature of winding

TN

°C

130

130

Rated data

 

 

 

 

Rated torque

MN

Nm

344

324

Rated current

IN

A

10

15

Maximum speed at rated torque

nMAX,MN

rpm

96

200

Rated power dissipation

PV,N

kW

3.73

3.71

Limit data

 

 

 

 

Maximum torque

MMAX

Nm

614

614

Maximum current

IMAX

A

20

32

Electric power of motor at MMAX

PEL,MAX

kW

14.2

19.7

Maximum speed at maximum torque

nMAX,MMAX

rpm

21

110

No-load speed

nMAX,0

rpm

190

300

Torque at n = 1 [rpm]

M0

Nm

361

361

Current at M0 and n = 1 [rpm]

I0

A

10

17

Thermal static torque

M0*

Nm

256

256

Thermal stall current

I0*

A

7.6

12

Physical constants

 

 

 

 

Torque constant at 20 °C

kT,20

Nm/A

34

21.4

Voltage constant

kE

V/(1000/min)

2056

1295

Motor constant at 20 °C

kM,20

Nm/(W)0.5

6.11

6.13

Thermal time constant

tTH

s

60

60

No. of pole pairs

p

-

33

33

Cogging torque

MCOG

Nm

1.8

1.8

Stator mass

mS

kg

11.9

11.9

Rotor mass

mL

kg

6.3

6.3

Rotor moment of inertia

JL

10-2kgm2

8.92

8.92

Phase resistance of winding at 20 °C

RSTR, 20

Ω

7.41

2.92

Phase inductance of winding

LSTR

mH

21

8.3

Data, main motor cooler

 

 

 

 

Maximum dissipated thermal power

QH,MAX

kW

3.1

3.09

Recommended minimum volume flow rate

H,MIN

l/min

5.2

5.2

Temperature increase of the coolant

ΔTH

K

8.6

8.5

Pressure drop

ΔpH

bar

0.2

0.2

192

 

 

 

1FW6 Built-in torque motors

 

Configuration Manual, 05/2009, 6SN1197-0AE00-0BP3

Page 191
Image 191
Siemens S120 configurationmanual Data sheet 1FW6130-xxB07-xxxx