Technical data and characteristics 14.2 Data sheets and diagrams

14.2.31FW6150-xxxxx-xxxx

Data sheet 1FW6150-xxB05-xxxx

Table 14- 9 1FW6150-xxB05-1Jxx, 1FW6150-xxB05-4Fxx

Technical data

Symbol

Unit

-xxB05-1Jxx

-xxB05-4Fxx

1FW6150

 

 

 

 

Boundary conditions

 

 

 

 

DC link voltages

UZK

V

600

600

Water cooling inlet temperature

TVORL

°C

35

35

Rated temperature of winding

TN

°C

130

130

Rated data

 

 

 

 

Rated torque

MN

Nm

338

298

Rated current

IN

A

17

36

Maximum speed at rated torque

nMAX,MN

rpm

230

650

Rated power dissipation

PV,N

kW

2.57

2.52

Limit data

 

 

 

 

Maximum torque

MMAX

Nm

710

710

Maximum current

IMAX

A

44

100

Electric power of motor at MMAX

PEL,MAX

kW

22.8

39.4

Maximum speed at maximum torque

nMAX,MMAX

rpm

110

330

No-load speed

nMAX,0

rpm

350

830

Torque at n = 1 [rpm]

M0

Nm

360

360

Current at M0 and n = 1 [rpm]

I0

A

18

44

Thermal static torque

M0*

Nm

255

255

Thermal stall current

I0*

A

12

30

Physical constants

 

 

 

 

Torque constant at 20 °C

kT,20

Nm/A

19.8

8.26

Voltage constant

kE

V/(1000/min)

1199

499.6

Motor constant at 20 °C

kM,20

Nm/(W)0.5

7.2

7.26

Thermal time constant

tTH

s

60

60

No. of pole pairs

p

-

33

33

Cogging torque

MCOG

Nm

1.8

1.8

Stator mass

mS

kg

17.9

17.9

Rotor mass

mL

kg

3.8

3.8

Rotor moment of inertia

JL

10-2kgm2

10.1

10.1

Phase resistance of winding at 20 °C

RSTR, 20

Ω

1.82

0.31

Phase inductance of winding

LSTR

mH

9.4

1.6

Data, main motor cooler

 

 

 

 

Maximum dissipated thermal power

QH,MAX

kW

2.13

2.1

Recommended minimum volume flow rate

H,MIN

l/min

4.5

4.5

198

 

 

 

1FW6 Built-in torque motors

 

Configuration Manual, 05/2009, 6SN1197-0AE00-0BP3

Page 197
Image 197
Siemens S120 configurationmanual 14.2.3 1FW6150-xxxxx-xxxx, Data sheet 1FW6150-xxB05-xxxx