System integration 7.1 System requirements

Note

In systems where direct drives are used on controlled infeeds, electrical oscillations can occur with respect to ground potential. These oscillations are, among other things, influenced by:

The lengths of the cables

The rating of the infeed/regenerative feedback module

The number of axes

The size of the motor

The winding design of the motor

The type of line supply

The place of installation

The oscillations lead to increased voltage loads and may damage the main insulation! We thus recommend using an HFD commutating reactor with damping resistance for damping the oscillations. For specific details, refer to the documentation of the drive system being used or contact your local Siemens office.

Accuracy

The accuracy of a direct drive with torque motor is governed by the:

Mechanical design of the machine

Control technology used

Resolution and measuring accuracy of the encoder

Mechanics

The potential machining accuracy of a drive system with torque motor is influenced by the:

Mechanical rigidity and noise immunity of the drive system

Running smoothness

The running smoothness in the axial and radial direction depends on the bearing version and its accuracy. The requirements here can be fulfilled by means of a suitable axes design.

Control quality

The control quality of a direct drive with torque motor is governed by the:

Rigidity of the drive system (dynamic quality of the housing and machine construction, bearing, encoder installation)

The precision when mounting and adjusting the encoder system

1FW6 Built-in torque motors