Motor components of the built-in motor and options

 

 

 

 

3.2 Thermal motor protection

Table 3- 3

Technical data of the KTY 84 PTC thermistor

 

Name

 

Description

 

Type

 

KTY 84

 

 

Transfer range

- 40 °C ... + 300 °C

 

Resistance when cold (20 °C)

approx. 580 Ω

 

Resistance when hot (100 °C)

approx. 1000 Ω

 

Connection

 

Connect signal cable with connector to SME12x module.

Application

 

Temperature monitoring to determine the motor utilization.

Temperature characteristic

 

 

 

 

 

 



 

 

 

5HVLVWDQFH˖



 

 

 



 

 

 

 

 

 

 

 



 

 

 

 



,7HVW P$

 

 

 

 

 

 

 



 

 

 

 



 

 

 

 

                  

 

 

 

 

7HPSHUDWXUHr&

DANGER

Electrical shock hazard!

To fulfill the requirements of electrical separation in accordance with EN 61800-5-1, it is not enough to connect the signal cable (cores ws and br) to the SMC20 Sensor Module. The temperature monitoring circuits must be connected to the drive control via the SME12x module.

NOTICE

When connecting temperature sensors with open cable ends, please pay attention to how the core colors are assigned (described in the section dealing with connections).

1FW6 Built-in torque motors

47

Configuration Manual, 05/2009, 6SN1197-0AE00-0BP3

Page 46
Image 46
Siemens S120 configurationmanual Thermal motor protection, Electrical shock hazard