Interfaces 8.2 Electrical connections
The cables for the power connection are brought out at the front of the stator (B side). The open cable ends must be connected in a terminal box, which must be provided by the machine manufacturer. Sufficient installation space must be provided in the axes construction. Standard
8.2.1 | Power connection |
| |
Connection assignment |
| ||
|
| Table 8- 4 Power connection for torque motor |
|
|
|
|
|
|
| Converter | Torque motor/stator |
|
| U2 | U |
|
| V2 | V |
|
| W2 | W |
For information on connecting the power, please also refer to the figures relating to system integration in the section titled "System requirements". The rotor rotates clockwise if the torque motor is connected to phase sequence U, V, W. Also refer to "Direction of rotation" in Chapter "Technical features".
8.2.2Signal connection
The temperature monitoring circuits must not be connected without a protection module.
DANGER
Electrical shock hazard!
The circuits of
Connecting the temperature monitoring circuits to the SMC20 Sensor Module does not fulfill the requirements of protective separation to EN
1FW6 | 143 |
Configuration Manual, 05/2009, |