Siemens S120 configurationmanual 228

Models: S120

1 301
Download 301 pages 40.03 Kb
Page 227
Image 227

Technical data and characteristics 14.2 Data sheets and diagrams

Technical data

Symbol

Unit

-xxB05-1Jxx

-xxB05-2Jxx

-xxB05-5Gxx

1FW6190

 

 

 

 

 

Temperature increase of the coolant

ΔTH

K

7.3

7.3

7.3

Pressure drop

ΔpH

bar

0.5

0.5

0.5

Data for precision motor cooler *)

 

 

 

 

 

Maximum dissipated thermal power

QP,MAX

kW

0.284

0.284

0.284

Recommended minimum volume flow rate

P,MIN

l/min

1.8

1.8

1.8

Temperature increase of the coolant

ΔTP

K

2.3

2.3

2.3

Pressure drop

ΔpH

bar

0.5

0.5

0.5

*) Parallel connection of main and precision motor cooler