Technical data and characteristics 14.2 Data sheets and diagrams

14.2Data sheets and diagrams

14.2.11FW6090-xxxxx-xxxx

Data sheet 1FW6090-xxB05-xxxx

Table 14- 1 1FW6090-xxB05-0Fxx, 1FW6090-xxB05-0Kxx

Technical data

Symbol

Unit

-xxB05-0Fxx

-xxB05-0Kxx

1FW6090

 

 

 

 

Boundary conditions

 

 

 

 

DC link voltages

UZK

V

600

600

Water cooling intake temperature

TVORL

°C

35

35

Rated temperature of winding

TN

°C

130

130

Rated data

 

 

 

 

Rated torque

MN

Nm

113

109

Rated current

IN

A

5.6

7.4

Maximum speed at rated torque

nMAX,MN

rpm

140

250

Rated power loss

PV,N

kW

2.19

2.12

Limit data

 

 

 

 

Maximum torque

MMAX

Nm

179

179

Maximum current

IMAX

A

9.5

13

Electric power of motor at MMAX

PEL,MAX

kW

6.55

8.12

Maximum speed at maximum torque

nMAX,MMAX

rpm

46

140

No-load speed

nMAX,0

rpm

310

430

Torque at n = 1 [rpm]

M0

Nm

119

119

Current at M0 and n = 1 [rpm]

I0

A

5.9

8.2

Thermal static torque

M0*

Nm

84.1

84.1

Thermal stall current

I0*

A

4.1

5.6

Physical constants

 

 

 

 

Torque constant at 20 °C

kT,20

Nm/A

20.8

15

Voltage constant

kE

V/(1000/min)

1258

906.2

Motor constant at 20 °C

kM,20

Nm/(W)0.5

2.64

2.68

Thermal time constant

tTH

s

60

60

No. of pole pairs

p

-

22

22

Cogging torque

MCOG

Nm

1.2

1.2

Stator mass

mS

kg

6.6

6.6

Rotor mass

mL

kg

2.6

2.6

Rotor moment of inertia

JL

10-2kgm2

1.52

1.52

Phase resistance of winding at 20 °C

RSTR, 20

Ω

14.9

7.5

Phase inductance of winding

LSTR

mH

47.1

24.4

182

 

 

 

1FW6 Built-in torque motors

 

Configuration Manual, 05/2009, 6SN1197-0AE00-0BP3

Page 181
Image 181
Siemens S120 configurationmanual Data sheets and diagrams, 14.2.1 1FW6090-xxxxx-xxxx, Data sheet 1FW6090-xxB05-xxxx